drivers: Fix signs in max31865 temperature calculation #68711

Merged
merged 1 commit into from
Feb 9, 2024

Conversation

tobias-roehmel
Copy link
Contributor

The reference document says that the formula for negative temperatures has two minus signs missing.

fixes #68710

The reference document says that the formula for negative
temperatures has two minus signs missing.

fixes zephyrproject-rtos#68710

Signed-off-by: Tobias Röhmel <[email protected]>
Copy link
Collaborator

@tristan-google tristan-google left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This looks correct to me based on page 4 of the referenced ADI app note

Copy link
Member

@MaureenHelm MaureenHelm left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Thanks for the fix!

@MaureenHelm MaureenHelm added the bug The issue is a bug, or the PR is fixing a bug label Feb 7, 2024
@MaureenHelm MaureenHelm added this to the v3.6.0 milestone Feb 7, 2024
@fabiobaltieri fabiobaltieri merged commit 20f1737 into zephyrproject-rtos:main Feb 9, 2024
23 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
area: Sensors Sensors bug The issue is a bug, or the PR is fixing a bug platform: ADI Analog Devices, Inc.
Projects
None yet
Development

Successfully merging this pull request may close these issues.

Wrong signs in negative temperature calculation for max31865
7 participants