Skip to content
forked from gianfrdp/SDM120C

sdm120ct ModBus Mini Smart Meter (those with TA probe, split core)

License

Notifications You must be signed in to change notification settings

segaura/SDM120CT

 
 

Repository files navigation

SDM120C

SDM120C ModBus RTU client to read EASTRON SDM smart mini power meter registers

It depends on libmodbus (http://libmodbus.org)

To compile make clean && make

To install make install

To uninstall make uninstall

# SDM120C
SDM120C ModBus RTU client to read EASTRON SDM120C smart mini power meter registers

It works with SDM120C and SDM220 models

It depends on libmodbus (http://libmodbus.org)

To compile and install
  make clean && make install

Usage: sdm120c [-a address] [-d] [-x] [-p] [-v] [-c] [-e] [-i] [-t] [-f] [-g] [-T] [[-m]|[-q]] [-b baud_rate] [-P parity] [-S bit] [-z num_retries] [-j seconds] [-w seconds] [-1 | -2] device
       sdm120c [-a address] [-d] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] -s new_address device
       sdm120c [-a address] [-d] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] -r baud_rate device 
       sdm120c [-a address] [-d] [-b baud_rate] [-P parity] [-S bit] [-1 | -2] -R new_time device

where
    -a address     Meter number (between 1 and 247). Default: 1
    -s new_address Set new meter number (between 1 and 247)
    -p             Get power (W)
    -v             Get voltage (V)
    -c             Get current (A)
    -f             Get frequency (Hz)
    -g             Get power factor
    -e             Get exported energy (Wh)
    -i             Get imported energy (Wh)
    -t             Get total energy (Wh)
    -T             Get Time for rotating display values (0 = no rotation) 
    -d             Debug
    -x             Trace (libmodbus debug on)
    -b baud_rate   Use baud_rate serial port speed (1200, 2400, 4800, 9600)
                   Default: 2400
    -P parity      Use parity (E, N, O)
    -S bit         Use stop bits (1, 2). Default: 1
    -r baud_rate   Set baud_rate meter speed (1200, 2400, 4800, 9600)
    -R new_time    Change rotation time for displaying values (0 - 30s) (0 = no totation)
    -m             Output values in IEC 62056 format ID(VALUE*UNIT)
    -q             Output values in compact mode
    -z num_retries Try to read max num_retries times on bus before exiting
                   with error. Default: 1 (no retry)
    -j 1/10 secs   Response timeout. Default: 2=0.2s
    -D 1/1000 secs Delay before sending commands (wait line set). Default: 30=0.03s
    -w seconds     Time to wait to lock serial port. (1-30s) Default: 0s
    -1             Model: SDM120C (default)
    -2             Model: SDM220
    device         Serial device, i.e. /dev/ttyUSB0

Serial device is required. When no parameter is passed, retrives all values

About

sdm120ct ModBus Mini Smart Meter (those with TA probe, split core)

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C 68.7%
  • Python 15.9%
  • PHP 12.1%
  • Shell 2.8%
  • Makefile 0.5%