version 30-Sept-2016
neurolabusc
released this
07 Oct 16:17
·
1203 commits
to master
since this release
30-Sept-2016
- Save ImageType (0x0008,0x0008) to BIDS.
- Separate CT scans with different exposures.
- Fixed issues where some compilers would generate erratic filenames for zero-padded series (e.g. "-f %3s")
- Reduce verbosity (reduce number of repeated warnings, less scary warnings for derived rather than raw images).
- Re-enable custom output directory "-o" option broken by 30-Apr-2016 version.
- Deal with mis-behaved GE CT images where slice direction across images is not consistent.
- Add new BIDS fields (field strength, manufacturer, etc).
- Philips PAR/REC conversion now reports inconsistent requested vs measured TR (due to prospect. motion corr.?)
- GE: Locations In Acquisition (0054, 0081) is inaccurate if slices are interpolated, use Images In Acquisition (0020,1002) if available
- New filename options %d Series description (0008,103E), %z Sequence Name (0018,0024)
- New filename options %a antenna (coil) number, %e echo number
- Initialize unused portions of NIfTI header to zero so multiple runs always produce identical results
- Supports 3D lossless JPEG saved as multiple fragments