Skip to content

Contains six residential archetypes calibrated for Whapmagoostui-Kuujjjuarapik, QC

Notifications You must be signed in to change notification settings

polymtl-bee/whapmagoostui-kuujjuarapik-archetypes

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

3 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

whapmagoostui-kuujjuarapik-archetypes

This folder contains the set of six residential building archetypes referred to in the article "An archetype-based energy modeling approach for a remote, subarctic community". Each of the six subfolders contains all of the files required for simulation and is made up of the following:

  • The multizone building model (.b18)
  • The TRNSYS project file (.tpf)
  • A weather file for the CWEC20 typical meteorological year (.epw)
  • Text files which are read as an input by the TRNSYS project file

The TRNSYS project file was developed in TRNSYS version 18.02. It contains the following components:

  • Building characteristics (Equation Block): the set of unique characteristics for the archetype
  • EquipCons (Equation Block): calculates the daily power consumption of each appliance, hot water consumption, and the latent and sensible gains of sinks, baths and showers from Building America Protocols
  • Lighting (Type 9): reads an input file with the hourly lighting energy use fractions for a year (lighting.txt)
  • Hrly Usage Multiplier (Type 9): reads an input file with the hourly fractions for equipment energy use, occupancy and hot water draws, as well as the heating setpoint (equip_schedule.txt)
  • EquipSched (Equation Block): calculates the hourly values for power consumption of appliances and lighting, occupancy, hot water draws and the associated latent and sensible gains
  • Weather (Type 15): reads the input weather file (CAN_QC_KUUJJUARAPIK-A_7103537_CWEC2020.epw)
  • Type2260: takes the wind speed at the weather station height given in the weather file and extrapolates it to the height of the building for use in the Sherman-Grimsrud infiltration model
  • Type75b: calculates the infiltration air changes per hour for the building using the Sherman-Grimsrud method
  • Type760: calculates the properties of supply and exhaust air in the heat recovery ventilator
  • Slab Temp (Type 9) - only in WBG-Duplex, WBG-SF and WSG-SF: reads an input file of soil node temperatures adjacent to the foundation of the building (these temperatures were calculated in a preprocessing simulation using the Type1244 ground coupling component and typical soil temperatures from Whapmagoostui-Kuujjuarapik over a 20-year period)
  • Building (Type 56): a multizone building model containing the building geometry, envelope characteristics, and zone internal gains
  • PostProc (Equation Block): calculates default simulation outputs
  • Summary (Printegrator): prints the monthly summaries of heating, hot water and electricity loads

About

Contains six residential archetypes calibrated for Whapmagoostui-Kuujjjuarapik, QC

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published