DellOpenManage Powershell Module

Install Module

Requirements

  • PowerShell 5+
  • OpenManage Enterprise 3.4+
  • OpenManage Enterprise Modular 1.20.00+

PowerShell Gallery Installation

Install-Module -Name DellOpenManage -Scope CurrentUser

Scripted Installation

  1. Open PowerShell Command Window
  2. Change your PowerShell Execution Policy Set-ExecutionPolicy -ExecutionPolicy RemoteSigned -Scope CurrentUser
  3. CD to the directory where you cloned the Github repo
  4. .\Install-Module.ps1

Manual Installation

  1. Determine module path $Env:PSModulePath
    • PowerShell 5: C:\Users\username\Documents\WindowsPowerShell\Modules
    • PowerShell 6+: C:\Users\username\Documents\PowerShell\Modules
  2. Copy the DellOpenManage folder to a directory in your module path
    • Example: C:\Users\username\Documents\WindowsPowerShell\Modules\DellOpenManage
  3. List available Modules Get-Module Dell* -ListAvailable
  4. Import module Import-Module DellOpenManage

Contributing

See Contributing

Command Reference

See Command Reference

Getting Started

See if Module is available

Get-Module Dell* -ListAvailable

List available commandlets in Module

Get-Command -Module "DellOpenManage"

Show help for commandlet

Get-Help Connect-OMEServer -Detailed

Basic Example

  • Copy and paste these commands into a Test.ps1 script or PowerShell ISE and execute the script.
  • This will Import the Module, connect to server prompting for credentials, list servers by model, then disconnect the current session.
Import-Module DellOpenManage

Connect-OMEServer -Name "ome.example.com" -Credentials $(Get-Credential) -IgnoreCertificateWarning

"PowerEdge R640" | Get-OMEDevice -FilterBy "Model" | Format-Table

Disconnect-OMEServer

Connect

Connect

$credentials = New-Object -TypeName System.Management.Automation.PSCredential -ArgumentList "admin", $(ConvertTo-SecureString -Force -AsPlainText "password")
Connect-OMEServer -Name "ome.example.com" -Credentials $credentials -IgnoreCertificateWarning

Connect: Variables

. "C:\Path\To\Credentials.ps1"
$credentials = New-Object -TypeName System.Management.Automation.PSCredential -ArgumentList $OMEUsername, $(ConvertTo-SecureString -Force -AsPlainText $OMEPassword)
Connect-OMEServer -Name $OMEServer -Credentials $credentials -IgnoreCertificateWarning

Connect: Prompt for Credentials

$credentials = Get-Credential
Connect-OMEServer -Name "ome.example.com" -Credentials $credentials -IgnoreCertificateWarning

Discovery

Discover servers by hostname

New-OMEDiscovery -Name "TestDiscovery01" -Hosts @('server01-idrac.example.com') -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait

Discover servers by IP Address

New-OMEDiscovery -Name "TestDiscovery01" -Hosts @('10.35.0.0', '10.35.0.1') -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait

Discover servers by Subnet

New-OMEDiscovery -Name "TestDiscovery01" -Hosts @('10.37.0.0/24') -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait

Discover servers by Subnet every Sunday at 12:00AM UTC

New-OMEDiscovery -Name "TestDiscovery01" -Hosts @('10.37.0.0/24') -Schedule "RunLater" -ScheduleCron "0 0 0 ? * sun *" -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Replace host list and run now

"TestDiscovery01" | Get-OMEDiscovery | Edit-OMEDiscovery -Hosts @('server01-idrac.example.com') -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Append host to host list and run now

"TestDiscovery01" | Get-OMEDiscovery | Edit-OMEDiscovery -Hosts @('server02-idrac.example.com') -Mode "Append" -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Remove host from host list and run now

"TestDiscovery01" | Get-OMEDiscovery | Edit-OMEDiscovery -Hosts @('server02-idrac.example.com') -Mode "Remove" -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Run discovery job now

"TestDiscovery01" | Get-OMEDiscovery | Edit-OMEDiscovery -Schedule "RunNow" -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Run discovery job every Sunday at 12:00AM UTC

"TestDiscovery01" | Get-OMEDiscovery | Edit-OMEDiscovery -Schedule "RunLater" -ScheduleCron "0 0 0 ? * sun *" -DiscoveryUserName "root" -DiscoveryPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Wait -Verbose

Devices

Get device by id

10097, 10100 | Get-OMEDevice -FilterBy "Id" | Format-Table

Get device by service tag

"C86F0ZZ", "3XMHHZZ" | Get-OMEDevice -FilterBy "ServiceTag" | Format-Table

Get device by name

"R620.example.com" | Get-OMEDevice -FilterBy "Name" | Format-Table

Get device by model

"PowerEdge R640" | Get-OMEDevice -FilterBy "Model" | Format-Table

Get device by group

Get-OMEDevice -Group $(Get-OMEGroup "Servers_Win") | Format-Table
"Servers_ESXi", "Servers_Win" | Get-OMEGroup | Get-OMEDevice | Format-Table

Create separate inventory refresh job for each device in list

"PowerEdge R640" | Get-OMEDevice -FilterBy "Model" | Invoke-OMEInventoryRefresh -Verbose

Create one inventory refresh job for all devices in list. Notice the preceeding comma before the device list.

,$("PowerEdge R640" | Get-OMEDevice -FilterBy "Model") | Invoke-OMEInventoryRefresh -Verbose

Device Details

Get all inventory

10097, 10100 | Get-OMEDevice -FilterBy "Id" | Get-OMEDeviceDetail

Get network cards and mac addresses

"C39P9ZZ", "C39N9ZZ" | Get-OMEDevice | Get-OMEDeviceDetail -InventoryType "serverNetworkInterfaces" | Format-Table

Get firmware inventory

"C39P9ZZ", "C39N9ZZ" | Get-OMEDevice | Get-OMEDeviceDetail -InventoryType "deviceSoftware" | Format-Table

Inventory Types

These are device specific. A full list can be found by querying the OME API at /api/DeviceService/Devices(DeviceId)/InventoryTypes

deviceCapabilities
serverDeviceCards
chassisControllerList
chassisFansList
chassisPciDeviceList
chassisPowerSupplies
chassisSlotsList
chassisStorageComputeAssociations
chassisTemperatureList
serverRaidControllers
serverProcessors
serverArrayDisks
serverFcCards
serverVirtualFlashes
deviceFru
deviceLicense
deviceLocation
deviceManagement
serverMemoryDevices
serverNetworkInterfaces
serverOperatingSystems
serverSupportedPowerStates
serverPowerSupplies
deviceSoftware
serverStorageEnclosures
subsystemRollupStatus

Groups

Get all groups

Get-OMEGroup | Format-Table

Get group by name

Get-OMEGroup "R640Test" | Format-Table

Create a new static group

New-OMEGroup -Name "Test Group 01"

Edit group name and description

Get-OMEGroup "Test Group 01" | Edit-OMEGroup -Name "Test Group 001" -Description "This is a new group"

Add devices to group

Get-OMEGroup "Test Group 01" | Edit-OMEGroup -Devices $("PowerEdge R640" | Get-OMEDevice -FilterBy "Model")

Remove devices from group

Get-OMEGroup "Test Group 01" | Edit-OMEGroup -Mode "Remove" -Devices $("PowerEdge R640" | Get-OMEDevice -FilterBy "Model")

Remove group

Get-OMEGroup "Test Group 01" | Remove-OMEGroup

Power

Power on server

Set-OMEPowerState -State "On" -Devices $("37KP0ZZ" | Get-OMEDevice -FilterBy "ServiceTag")

Firmware

Create new firmware catalog that points to downloads.dell.com

New-OMECatalog -Name "Test01"

Create new firmware catalog to a CIFS share (Requires Dell Repository Manager)

New-OMECatalog -Name "CIFSTest" -RepositoryType "CIFS" -Source "windows01.example.com" -SourcePath "/Share01/DRM/AllDevices" -CatalogFile "AllDevices_1.01_Catalog.xml" -DomainName "example.com" -Username "Administrator" -Password $("P@ssword1" | ConvertTo-SecureString -AsPlainText -Force)

Create new firmware catalog to a NFS share (Requires Dell Repository Manager)

New-OMECatalog -Name "NFSTest" -RepositoryType "NFS" -Source "nfs01.example.com" -SourcePath "/mnt/data/drm/AllDevices" -CatalogFile "AllDevices_1.01_Catalog.xml"

Get firmware catalog

Get-OMECatalog | Format-Table
"DRM" | Get-OMECatalog | Format-Table

Get firmware baseline

Get-OMEFirmwareBaseline | Format-Table
"AllLatest" | Get-OMEFirmwareBaseline | Get-OMEFirmwareCompliance | Format-Table

Get device firmware compliance report

$devices = $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag")
"AllLatest" | Get-OMEFirmwareBaseline | Get-OMEFirmwareCompliance -DeviceFilter $devices |
    Select-Object -Property ServiceTag,DeviceModel,DeviceName,CurrentVersion,Version,UpdateAction,ComplianceStatus,Name | Format-Table

Get device firmware compliance report. BIOS only.

"AllLatest" | Get-OMEFirmwareBaseline | Get-OMEFirmwareCompliance -ComponentFilter "BIOS" |
    Select-Object -Property ServiceTag,DeviceModel,DeviceName,CurrentVersion,Version,UpdateAction,ComplianceStatus,Name |
    Sort-Object CurrentVersion | Format-Table

Get device firmware compliance report. Multiple component filter

"AllLatest" | Get-OMEFirmwareBaseline | Get-OMEFirmwareCompliance -ComponentFilter "BIOS", "iDRAC" |
    Select-Object -Property ServiceTag,DeviceModel,DeviceName,CurrentVersion,Version,UpdateAction,ComplianceStatus,Name |
    Sort-Object CurrentVersion | Format-Table

Create new firmware baseline

$catalog = $("Auto-Update-Online" | Get-OMECatalog)
$devices = $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag")
New-OMEFirmwareBaseline -Name "TestBaseline01" -Catalog $catalog -Devices $devices

Create new firmware baseline for downgrades

$catalog = $("Auto-Update-Online" | Get-OMECatalog)
$devices = $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag")
New-OMEFirmwareBaseline -Name "TestBaseline01" -Catalog $catalog -Devices $devices -AllowDowngrade

Display device compliance report for all devices in baseline. No updates are installed by default.

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) | Format-Table

Update firmware on all devices in baseline immediately ***Warning: This will force a reboot of all servers

$devices = $("CY85DZZ" | Get-OMEDevice -FilterBy "ServiceTag")
$baseline = $("AllLatest" | Get-OMEFirmwareBaseline)
Update-OMEFirmware -Baseline $baseline -UpdateSchedule "RebootNow" -Wait

Update firmware on all devices in baseline on next reboot

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -UpdateSchedule "StageForNextReboot"

Update firmware on specific devices in baseline immediately ***Warning: This will force a reboot of all servers

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -DeviceFilter $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -UpdateSchedule "RebootNow" -Wait

Downgrade firmware on specific devices in baseline immediately ***Warning: This will force a reboot of all servers

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -DeviceFilter $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -UpdateSchedule "RebootNow" -UpdateAction "Downgrade" -Wait

Update firmware on specific components in baseline on next reboot and clear job queue

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -ComponentFilter "iDRAC" -UpdateSchedule "StageForNextReboot" -ClearJobQueue

Update firmware later scheduled at 11/1/2020 12:00AM UTC

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -DeviceFilter $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -UpdateSchedule "ScheduleLater" -UpdateScheduleCron "0 0 0 1 11 ?"

Templates

Get all templates

Get-OMETemplate | Format-Table

Get template by name

"DRM" | Get-OMETemplate | Format-Table

Get template by type

"Deployment" | Get-OMETemplate -FilterBy "Type" | Format-Table

Get template when templates with similar names exist

Get-OMETemplate | Where-Object -Property "Name" -EQ "Test Template "

Create new deployment template from source device

New-OMETemplateFromDevice -Name "TestTemplate" -Device $("37KP0ZZ" | Get-OMEDevice -FilterBy "ServiceTag") -Wait

Create new deployment template from source device and capture specific components

New-OMETemplateFromDevice -Name "TestTemplate" -Component "iDRAC", "BIOS" -Device $("37KP0ZZ" | Get-OMEDevice -FilterBy "ServiceTag") -Wait

Create new deployment template from XML string

$xml = @'
<SystemConfiguration>
    <Component FQDD="iDRAC.Embedded.1">
        <Attribute Name="Users.5#UserName">testuser</Attribute>
    </Component>
</SystemConfiguration>
'@
New-OMETemplateFromFile -Name "TestTemplate" -Content $xml

Create new deployment template from XML file

New-OMETemplateFromFile -Name "TestTemplate" -Content $(Get-Content -Path .\Data.xml | Out-String)

Deploy template to device

"TestTemplate" | Get-OMETemplate | Invoke-OMETemplateDeploy -Devices $("37KP0ZZ" | Get-OMEDevice) -Wait

Deploy template and boot to network ISO over NFS

"TestTemplate" | Get-OMETemplate | Invoke-OMETemplateDeploy -Devices $("37KP0ZZ" | Get-OMEDevice) -NetworkBootShareType "NFS" -NetworkBootShareIpAddress "192.168.1.100" -NetworkBootIsoPath "/mnt/data/iso/CentOS7-Unattended.iso" -Wait

Deploy template and boot to network ISO over CIFS

"TestTemplate" | Get-OMETemplate | Invoke-OMETemplateDeploy -Devices $("37KP0ZZ" | Get-OMEDevice) -NetworkBootShareType "CIFS" -NetworkBootShareIpAddress "192.168.1.101" -NetworkBootIsoPath "/Share/ISO/CentOS7-Unattended.iso" -NetworkBootShareUser "Administrator" -NetworkBootSharePassword "Password" -NetworkBootShareName "Share" -Wait

Clone template using default name "TestTemplate01 - Clone"

"TestTemplate01" | Get-OMETemplate | Copy-OMETemplate

Clone template using default name "TestTemplate01 - Clone" when multiple templates with similar names exist

$(Get-OMETemplate | Where-Object -Property "Name" -EQ "TestTemplate") | Copy-OMETemplate

Clone template and specify new name

"TestTemplate01" | Get-OMETemplate | Copy-OMETemplate -Name "TestTemplate02"

Clone template including Identity Pool, VLANs and Teaming

"TestTemplate01" | Get-OMETemplate | Copy-OMETemplate -All

Configuration Compliance

Get template by type

"Configuration" | Get-OMETemplate -FilterBy "Type" | Format-Table

Create new configuration compliance template from source device

New-OMETemplateFromDevice -Name "TestTemplate" -TemplateType "Configuration" -Device $("37KP0ZZ" | Get-OMEDevice -FilterBy "ServiceTag") -Wait

Create new configuration compliance template from XML file

New-OMETemplateFromFile -Name "TestTemplate" -TemplateType "Configuration" -Content $(Get-Content -Path .\Data.xml | Out-String)

Create new configuration compliance baseline

New-OMEConfigurationBaseline -Name "TestBaseline01" -Template $("Template01" | Get-OMETemplate -FilterBy "Name") -Devices $("37KPZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -Wait -Verbose

Update configuration compliance on all devices in baseline This will force a reboot if necessary

Update-OMEConfiguration -Name "Make Compliant Test01" -Baseline $("TestBaseline01" | Get-OMEConfigurationBaseline) -Wait -Verbose

Update configuration compliance on filtered devices in baseline This will force a reboot if necessary

Update-OMEConfiguration -Name "Make Compliant Test01" -Baseline $("TestBaseline01" | Get-OMEConfigurationBaseline) -DeviceFilter $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -Wait -Verbose

Update configuration compliance on filtered devices in baseline staging changes for next reboot

Update-OMEConfiguration -Name "Make Compliant Test01" -Baseline $("TestBaseline01" | Get-OMEConfigurationBaseline) -DeviceFilter $("C86CZZZ" | Get-OMEDevice -FilterBy "ServiceTag") -UpdateSchedule "StageForNextReboot" -Wait -Verbose

Check configuration compliance for baseline

$("TestBaseline01" | Get-OMEConfigurationBaseline -FilterBy "Name") | Invoke-OMEConfigurationBaselineRefresh -Wait -Verbose

Profiles

Get Profile by ProfileName

"ProfileName" | Get-OMEProfile

Get Profile by ProfileName where ProfileName includes single quotes. Use for Profiles deployed from Templates on the MX platform

Get-OMEProfile | Where-Object { $_.ProfileName -eq "Profile from template 'Test Template 01' 00001" }

Get Profile by TemplateName

"TemplateName" | Get-OMEProfile -FilterBy TemplateName

Create a new Profile from a Template

"Test Template 01" | Get-OMETemplate | New-OMEProfile -NamePrefix "Test Profile" -NumberOfProfilesToCreate 3 

Create a new Profile from a Template and mount ISO from NFS share to Virtual Media

"Test Template 01" | Get-OMETemplate | New-OMEProfile -NamePrefix "Test Profile" -NumberOfProfilesToCreate 3 -NetworkBootShareType "NFS" -NetworkBootShareIpAddress "192.168.1.100" -NetworkBootIsoPath "/mnt/data/iso/OS.iso" -Verbose

Assign Profile to Device

$Device = "933NCZZ" | Get-OMEDevice
"Test Profile 00001" | Get-OMEProfile | Invoke-OMEProfileAssign -TargetId $Device.Id -Verbose
Invoke-OMEProfileUnassign -ProfileName "TSTest 00001" -Wait -Verbose

Assign Profile to Chassis Slot 1 and Apply Immediately This will force a reseat of the sled

*See https://www.dell.com/support/kbdoc/en-us/000214041/mx7000-deploying-a-slot-based-template-shows-the-profile-as-assigned-and-virtual-identities-as-reserved

$Chassis = "933MCZZ" | Get-OMEDevice
$ChassisSlots = $Chassis | Get-OMEDeviceDetail -InventoryType "chassisSlotsList" | Select-Object -ExpandProperty InventoryInfo
$SlotId = $ChassisSlots | Where-Object { $_.Number -eq "1" -and $_.DeviceType -eq 1000 } | Select-Object -ExpandProperty Id
"Test Profile 00001" | Get-OMEProfile | Invoke-OMEProfileAssign -TargetId $SlotId -AttachAndApply -Wait -Verbose

Unassign Profile by device

Invoke-OMEProfileUnassign -Device $("37KP0ZZ" | Get-OMEDevice) -Wait -Verbose

Unassign Profile on multiple devices

$("37KP0ZZ", "37KT0ZZ" | Get-OMEDevice) | Invoke-OMEProfileUnassign -Wait -Verbose

Unassign Profile by template

Invoke-OMEProfileUnassign -Template $("TestTemplate01" | Get-OMETemplate) -Wait -Verbose

Unassign Profile by profile name and force reclaim identities

Invoke-OMEProfileUnassign -ProfileName "Profile from template 'TestTemplate01' 00001" -ForceReclaim -Wait -Verbose

Remove Profile

"TestProfile01" | Get-OMEProfile | Remove-OMEProfile

Rename Profile

"Profile 00005" | Get-OMEProfile | Invoke-OMEProfileRename -Name "Test Profile 00005"

Rename Profile deployed from Template on MX platform

Get-OMEProfile | Where-Object { $_.ProfileName -eq "Profile from template 'Test Template 01' 00001" } | Invoke-OMEProfileRename -Name "Test Profile 01 - 00001"

Jobs

List all jobs

Get-OMEJob | Format-Table

Get job details by Id

13852 | Get-OMEJob -Detail -Verbose

Get job by job type

5 | Get-OMEJob -FilterBy "Type" | Format-Table

Get job by last run status

2060 | Get-OMEJob -FilterBy "LastRunStatus" | Format-Table

Get job by state

"Enabled" | Get-OMEJob -FilterBy "State" | Format-Table

Export job details to CSV by Id

10085 | Get-OMEJob -FilterBy "Id" -Detail | Select-Object  @{Name='JobId'; Expression='Id'}, JobName, JobTypeId, JobType, JobDescription, LastRun -ExpandProperty JobDetail
    | Export-Csv -Path "C:\Temp\OMEJobDetail.csv" -NoTypeInformation

Get jobs filter by multiple properties

2070 | Get-OMEJob -FilterBy "LastRunStatus" | Where-Object JobTypeId -EQ 101

Run job

28991 | Invoke-OMEJobRun -Wait -Verbose

Reports

Run report

Invoke-Report -ReportId 11709

Alerts

Get 50 most recent critical alerts

Get-OMEAlert -SeverityType CRITICAL -Top 50 -Pages 1

Get all alert policies

Get-OMEAlertPolicy

Get alert policy by ID

12016 | Get-OMEAlertPolicy

Get alert policy by Name (OME API does not currently support filtering by Name natively)

Get-OMEAlertPolicy | Where-Object { $_.Name -eq "Group A Alert" }

Enable Alert Policy

17758 | Get-OMEAlertPolicy | Enable-OMEAlertPolicy

Disable Alert Policy

17758 | Get-OMEAlertPolicy | Disable-OMEAlertPolicy

Disable Multiple Alert Policies

$AlertPolicies = Get-OMEAlertPolicy | Where-Object { $_.Name -match "Group A Alert" }
Disable-OMEAlertPolicy -AlertPolicy $AlertPolicies

Create alert policy

Use 17758 | Get-OMEAlertPolicy | ConvertTo-Json -Depth 10 to show an existing policy as an example

$NewAlertPolicy = '{
    "Name": "Test Alert Policy",
    "Description": null,
    "Enabled": true,
    "DefaultPolicy": false,
    "PolicyData": {
        "Catalogs": [
            {
                "CatalogName": "iDRAC",
                "Categories": [
                    0
                ],
                "SubCategories": [
                    0
                ]
            }
        ],
        "Severities": [
            16
        ],
        "MessageIds": [],
        "Devices": [],
        "DeviceTypes": [],
        "Groups": [
            17745,
            17743,
            17746
        ],
        "AllTargets": false,
        "Schedule": {
            "StartTime": "2023-03-21 04:00:00.017",
            "EndTime": "",
            "CronString": "* * * ? * * *",
            "Interval": false
        },
        "Actions": [
            {
                "Id": 36,
                "Name": "Email",
                "ParameterDetails": [
                    {
                        "Id": 1,
                        "Name": "subject",
                        "Value": "Device Name: $name,  Device IP Address: $ip,  Severity: $severity",
                        "Type": "string",
                        "TypeParams": [
                            {
                                "Name": "maxLength",
                                "Value": "255"
                            }
                        ]
                    },
                    {
                        "Id": 1,
                        "Name": "to",
                        "Value": "[email protected]",
                        "Type": "string",
                        "TypeParams": [
                            {
                                "Name": "maxLength",
                                "Value": "255"
                            }
                        ]
                    },
                    {
                        "Id": 1,
                        "Name": "from",
                        "Value": "[email protected]",
                        "Type": "string",
                        "TypeParams": [
                            {
                                "Name": "maxLength",
                                "Value": "255"
                            }
                        ]
                    },
                    {
                        "Id": 1,
                        "Name": "message",
                        "Value": "Event occurred for Device Name: $name, Device IP Address: $ip, Identifier: $identifier, UTC Time: $time, Severity: $severity, Message ID: $messageId, $message",
                        "Type": "string",
                        "TypeParams": [
                            {
                                "Name": "maxLength",
                                "Value": "255"
                            }
                        ]
                    }
                ],
                "TemplateId": 50
            }
        ],
        "UndiscoveredTargets": []
    },
    "State": true
}'

New-OMEAlertPolicy -AlertPolicy $NewAlertPolicy

Directory Services

Active Directory

Test AD Directory Service using Global Catalog Lookup

New-OMEDirectoryService -Name "LAB.LOCAL" -DirectoryType "AD" `
    -DirectoryServerLookup "DNS" -DirectoryServers @("lab.local") -ADGroupDomain "lab.local" `
    -TestConnection -TestUserName "[email protected]" -TestPassword $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) -Verbose

Create AD Directory Service using Global Catalog Lookup

New-OMEDirectoryService -Name "LAB.LOCAL" -DirectoryType "AD" `
    -DirectoryServerLookup "DNS" -DirectoryServers @("lab.local") -ADGroupDomain "lab.local"

Create AD Directory Service using Global Catalog Lookup with Certificate Validation

New-OMEDirectoryService -Name "LAB.LOCAL" -DirectoryType "AD" -DirectoryServerLookup "DNS" -DirectoryServers @("lab.local") -ADGroupDomain "lab.local" -CertificateValidation -CertificateFile "C:\Temp\CA.cer"

Create AD Directory Service manually specifing Domain Controllers

New-OMEDirectoryService -Name "LAB.LOCAL" -DirectoryType "AD" `
    -DirectoryServerLookup "MANUAL" -DirectoryServers @("ad1.lab.local", "ad2.lab.local") -ADGroupDomain "lab.local"

Import directory group

$AD = Get-OMEDirectoryService -DirectoryType "AD" -Name "LAB.LOCAL"
$ADGroups = Get-OMEDirectoryServiceSearch -Name "Admin" -DirectoryService $AD
$Role = Get-OMERole -Name "chassis"
Invoke-OMEDirectoryServiceImportGroup -DirectoryService $AD -DirectoryGroups $ADGroups -DirectoryType "AD" -UserName "[email protected]" -Password $(ConvertTo-SecureString 'calvin' -AsPlainText -Force)) -Role $Role -Verbose

LDAP

Create LDAP Directory Service

New-OMEDirectoryService -Name "LAB.LOCAL" -DirectoryType "LDAP" `
    -DirectoryServerLookup "MANUAL" -DirectoryServers @("ldap1.lab.local", "ldap2.lab.local") `
    -LDAPBaseDistinguishedName "dc=lab,dc=local"

Backup

Restore must be performed in OME-M at this time

Backup chassis to CIFS share now

$MXChassis = @("LEAD" | Get-OMEMXDomain | Select-Object -First 1)

Invoke-OMEApplianceBackup -Chassis $MXChassis -Share "192.168.1.100" -SharePath "/SHARE" -ShareType "CIFS" `
    -UserName "Administrator" -Password $(ConvertTo-SecureString 'calvin' -AsPlainText -Force) `
    -BackupFile "BACKUP_$((Get-Date).ToString('yyyyMMddHHmmss'))" `
    -IncludePw -IncludeCertificates -EncryptionPassword $(ConvertTo-SecureString 'nkQ*DTrNK7$b' -AsPlainText -Force) -Wait -Verbose

Backup chassis to NFS share now

$MXChassis = @("LEAD" | Get-OMEMXDomain | Select-Object -First 1)

Invoke-OMEApplianceBackup -Chassis $MXChassis -Share "192.168.1.100" -SharePath "/mnt/data/backup" -ShareType "NFS" `
    -BackupFile "BACKUP_$((Get-Date).ToString('yyyyMMddHHmmss'))" `
    -IncludePw -IncludeCertificates -EncryptionPassword $(ConvertTo-SecureString 'nkQ*DTrNK7$b' -AsPlainText -Force) -Wait -Verbose

Backup chassis to NFS share on schedule every Sunday at 12:00AM UTC

$MXChassis = @("LEAD" | Get-OMEMXDomain | Select-Object -First 1)

Invoke-OMEApplianceBackup -Chassis $MXChassis -Share "192.168.1.100" -SharePath "/mnt/data/backup" -ShareType "NFS" `
    -BackupFile "BACKUP_$((Get-Date).ToString('yyyyMMddHHmmss'))" -ScheduleCron '0 0 0 ? * sun *' `
    -IncludePw -IncludeCertificates -EncryptionPassword $(ConvertTo-SecureString 'nkQ*DTrNK7$b' -AsPlainText -Force) -Wait -Verbose

Services Plugin

Get Support cases for device by Service Tag

"C38V9T2" | Get-OMESupportAssistCase -Verbose

Export example json used to create new Support Assist group

New-OMESupportAssistGroup -ExportExampleJson 

Create new Support Assist group from file

New-OMESupportAssistGroup -AddGroup $(Get-Content "C:\Temp\Group.json" -Raw) -Verbose

Edit Support Assist group

$TestSupportAssistGroup = '{
    "MyAccountId": "",
    "Name": "Support Assist Group 2",
    "Description": "Support Assist Group",
    "DispatchOptIn": false,
    "CustomerDetails": null,
    "ContactOptIn":  false
}' 
"Support Assist Group 1" | Get-OMEGroup | Edit-OMESupportAssistGroup -EditGroup $TestSupportAssistGroup -Verbose

Add devices to Support Assist group

$devices = $("859N3L3", "759N3L3" | Get-OMEDevice -FilterBy "ServiceTag")
"Support Assist Group 1" | Get-OMEGroup | Edit-OMESupportAssistGroup -Devices $devices -Verbose

Remove devices from Support Assist group

$devices = $("859N3L3", "759N3L3" | Get-OMEDevice -FilterBy "ServiceTag")
"Support Assist Group 1"  | Get-OMEGroup | Edit-OMESupportAssistGroup -Mode "Remove" -Devices $devices -Verbose

Remove Support Assist group

"Support Assist Group 1" | Get-OMEGroup | Remove-OMESupportAssistGroup

Other Examples https://github.com/dell/OpenManage-PowerShell-Modules/blob/e8f150a122a16ab458d6cc18298ffe3ce94bf3b2/Examples/ServicesGroupCreateAddDevices.ps1

MX

Chassis

Create new Chassis Group

New-OMEMcmGroup -Name "TestLabMX"

Create new Chassis Group with VIP

New-OMEMcmGroup -Name "TestLabMX" -VIPIPv4Address "100.79.6.111" -VIPSubnetMask "255.255.254.0" -VIPGateway "100.79.7.254" -Wait -Verbose 

SmartFabric

Create new Smart Fabric

New-OMEFabric -Name "SmartFabric01" -DesignType "2xMX9116n_Fabric_Switching_Engines_in_same_chassis" `
    -SwitchAServiceTag "C38S9T2" -SwitchBServiceTag "CMWSV43" -Verbose

Configure Port Breakouts and Refresh Inventory

$SwitchA = $("C38S9T2" | Get-OMEDevice)
$SwitchB = $("CMWSV43" | Get-OMEDevice)

Set-OMEIOMPortBreakout -Device $SwitchA -BreakoutType "4X10GE" -PortGroups "port-group1/1/13" -Wait -Verbose
Set-OMEIOMPortBreakout -Device $SwitchA -BreakoutType "4X8GFC" -PortGroups "port-group1/1/15,port-group1/1/16" -Wait -Verbose
Set-OMEIOMPortBreakout -Device $SwitchB -BreakoutType "4X10GE" -PortGroups "port-group1/1/13" -Wait -Verbose
Set-OMEIOMPortBreakout -Device $SwitchB -BreakoutType "4X8GFC" -PortGroups "port-group1/1/15,port-group1/1/16" -Wait -Verbose
Invoke-OMEInventoryRefresh -Devices @($SwitchA, $SwitchB) -Wait

Create new Uplink

$SwitchA = $("C38S9T2" | Get-OMEDevice)
$SwitchB = $("CMWSV43" | Get-OMEDevice)
$DefaultNetworks = $("VLAN 1001", "VLAN 1003" | Get-OMENetwork)
$StorageFabricANetwork = $("Storage Fabric A" | Get-OMENetwork)
$StorageFabricBNetwork = $("Storage Fabric B" | Get-OMENetwork)
$Fabric = $("SmartFabric01" | Get-OMEFabric)
New-OMEFabricUplink -Name "EthernetUplink01" -Fabric $Fabric -UplinkType "Ethernet - No Spanning Tree" `
    -TaggedNetworks $DefaultNetworks -Ports "C38S9T2:ethernet1/1/41:1,CMWSV43:ethernet1/1/41:1" -Verbose
New-OMEFabricUplink -Name "StorageFabricAUplink" -Fabric $Fabric -UplinkType "FC Gateway" `
    -TaggedNetworks $StorageFabricANetwork -Ports "C38S9T2:fibrechannel1/1/43:1" -Verbose
New-OMEFabricUplink -Name "StorageFabricBUplink" -Fabric $Fabric -UplinkType "FC Gateway" `
    -TaggedNetworks $StorageFabricBNetwork -Ports "CMWSV43:fibrechannel1/1/43:1" -Verbose

Edit Uplink

$Fabric = "SmartFabric01" | Get-OMEFabric
$Uplink = "EthernetUplink01" | Get-OMEFabricUplink -Fabric $Fabric
$AddNetwork = "VLAN 1005", "VLAN 1006" | Get-OMENetwork
$UnTaggedNetwork = "default" | Get-OMENetwork
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -Name "NewUplinkName"
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -Mode "Append" -TaggedNetworks $AddNetwork -Verbose
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -Mode "Append" -Ports "C38S9T2:ethernet1/1/41:2,CMWSV43:ethernet1/1/41:2" -Verbose
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -Mode "Remove" -TaggedNetworks $AddNetwork -Ports "C38S9T2:ethernet1/1/41:2" -Verbose
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -Mode "Replace" -TaggedNetworks $AddNetwork -Ports "C38S9T2:ethernet1/1/41:1,CMWSV43:ethernet1/1/41:1" -Verbose
Edit-OMEFabricUplink -Fabric $Fabric -Uplink $Uplink -UnTaggedNetwork $UnTaggedNetwork -Verbose

Templates

Configure Template with Storage Networks

$DefaultNetworks = $("VLAN 1001", "VLAN 1003", "VLAN 1004", "VLAN 1005" | Get-OMENetwork)
$StorageFabricANetwork = $("Storage Fabric A" | Get-OMENetwork)
$StorageFabricBNetwork = $("Storage Fabric B" | Get-OMENetwork)
$Template = "MX740c 4 Port" | Get-OMETemplate 
$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 1 -TaggedNetworks $DefaultNetworks -Mode "Append" -Verbose
$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 2 -TaggedNetworks $DefaultNetworks -Mode "Append" -Verbose
$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 1 -TaggedNetworks $StorageFabricANetwork -Mode "Append" -Verbose
$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 2 -TaggedNetworks $StorageFabricBNetwork -Mode "Append" -Verbose

Remove Network from Template

$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 1 -TaggedNetworks $StorageFabricANetwork -Mode "Remove" -Verbose
$Template | Set-OMETemplateNetwork -NICIdentifier "NIC in Mezzanine 1A" -Port 2 -TaggedNetworks $StorageFabricBNetwork -Mode "Remove" -Verbose

Configure Template Identity Pool

$IdentityPool = $("default" | Get-OMEIdentityPool)
"MX740c 4 Port"  | Get-OMETemplate | Set-OMETemplateIdentityPool -IdentityPool $IdentityPool -Verbose

Set Chassis Name

$Chassis = "C38V9ZZ" | Get-OMEDevice
Set-OMEChassisName -Name "TESTMX7000-1" -Chassis $Chassis -Wait -Verbose

Set Chassis Slot Names

$Chassis = "C38V9ZZ" | Get-OMEDevice
Set-OMEChassisSlotName -Chassis $Chassis -Slot 1 -Name "MX840c-C39N9ZZ" -Wait -Verbose

Set-OMEChassisSlotName -Chassis $Chassis -Slot 1 -Name "MX5108-C38T9ZZ" -SlotType "IOM" -Wait -Verbose

Virtual Reseat

Trigger virtual system reseat

"933NCZZ" | Get-OMEDevice | Invoke-OMEDeviceReseat -Verbose -Wait

Quick Deploy

$RootPassword = $(ConvertTo-SecureString 'calvin' -AsPlainText -Force)
$Chassis = "C38V9ZZ" | Get-OMEDevice

Sleds DHCP

$QuickDeployDHCP = @(
    @{Slot=1;},
    @{Slot=2;}
)

Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "SLED" -Chassis $Chassis `
    -IPv4Enabled -IPv4NetworkType "DHCP" `
    -Slots $QuickDeployDHCP -Wait -Verbose

Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "SLED" -Chassis $Chassis `
    -IPv4Enabled -IPv4NetworkType "DHCP" `
    -IPv6Enabled -IPv6NetworkType "DHCP" `
    -Slots $QuickDeployDHCP -Wait -Verbose

Sleds IPv4 Only

$QuickDeployIPv4Static = @(
    @{Slot=1; IPv4Address="192.168.1.100"; VlanId=1}
)
Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "SLED" -Chassis $Chassis `
    -IPv4Enabled -IPv4NetworkType "STATIC" -IPv4SubnetMask "255.255.254.0" -IPv4Gateway "192.168.1.1" `
    -Slots $QuickDeployBothStatic -Verbose

Sleds IPv6 Only

$QuickDeployIPv6Static = @(
    @{Slot=1; IPv6Address="2001:0db8:85a3:0000:0000:8a2e:0370:7334"; VlanId=1},
    @{Slot=2; IPv6Address="2001:0db8:85a3:0000:0000:8a2e:0370:7335"; VlanId=1}
)
Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "SLED" -Chassis $Chassis `
    -IPv6Enabled -IPv6NetworkType "STATIC" -IPv6Gateway "fe80::1" -IPv6PrefixLength 4 `
    -Slots $QuickDeployIPv6Static -Verbose

Sleds IPv4 and IPv6

$QuickDeployBothStatic = @(
    @{Slot=1; IPv4Address="192.168.1.100"; IPv6Address="2001:0db8:85a3:0000:0000:8a2e:0370:7334"; VlanId=1}
)
Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "SLED" -Chassis $Chassis `
    -IPv4Enabled -IPv4NetworkType "STATIC" -IPv4SubnetMask "255.255.254.0" -IPv4Gateway "192.168.1.1" `
    -IPv6Enabled -IPv6NetworkType "STATIC" -IPv6Gateway "fe80::1" -IPv6PrefixLength 4 `
    -Slots $QuickDeployBothStatic -Verbose

IOM IPv4

$QuickDeployIPv4Static = @(
    @{Slot=1; IPv4Address="192.168.1.100"; VlanId=1}
)
Invoke-OMEQuickDeploy -RootPassword $RootPassword -SlotType "IOM" -Chassis $Chassis `
    -IPv4Enabled -IPv4NetworkType "STATIC" -IPv4SubnetMask "255.255.255.0" -IPv4Gateway "192.168.1.1" `
    -Slots $QuickDeployIPv4Static -Verbose

Application Settings

Set Application Settings

$Settings = @(
    @{Name="EmailAlertsConf.1#DestinationEmailAddress"; Value="mail.example.net"},
    @{Name="EmailAlertsConf.1#portNumber"; Value=25},
    @{Name="EmailAlertsConf.1#useSSL"; Value=$false},
    @{Name="ChassisLocation.1#DataCenterName"; Value="DC1"},
    @{Name="ChassisLocation.1#RoomName"; Value=""},
    @{Name="ChassisLocation.1#AisleName"; Value=""},
    @{Name="TimeConfig.1#NTPEnable"; Value=$true},
    @{Name="TimeConfig.1#TimeZone"; Value="TZ_ID_9"},
    @{Name="TimeConfig.1#NTPServer1"; Value="0.centos.pool.ntp.org"},
    @{Name="ChassisPower.1#RedundancyPolicy"; Value="GRID_REDUNDANCY"},
    @{Name="ChassisPower.1#EnableHotSpare"; Value=$true},
    @{Name="ChassisPower.1#PrimaryGrid"; Value="GRID_1"},
    @{Name="SessionConfiguration.1#maxSessions"; Value=100},
    @{Name="SSH.1#Enable"; Value=$true},
    @{Name="Preference.1#DeviceName"; Value="HOST_NAME"}
)

Set-OMEApplicationSettings -Settings $Settings -Wait -Verbose

Get Application Settings

$CurrentSettings = Get-OMEApplicationSettings
$CurrentSettings.SystemConfiguration.Components[0].Attributes | Format-Table

Error Handling and Control Flow

https://devblogs.microsoft.com/scripting/handling-errors-the-powershell-way

The -ErrorAction common parameter allows you to specify which action to take if a command fails. The available options are: Stop, Continue, SilentlyContinue, Ignore, or Inquire. By default, Windows PowerShell uses an error action preference of Continue, which means that errors will be written out to the host, but the script will continue to execute.

Troubleshooting

Verbose Output

  • Append -Verbose to any command

Redirect ALL output to file

Update-OMEFirmware -Baseline $("AllLatest" | Get-OMEFirmwareBaseline) -UpdateSchedule "StageForNextReboot" *> firmware.txt

Get PowerShell Version

$PSVersionTable

Get PowerShell Module Path

$env:PSModulePath

Support

This code is provided as-is and currently not officially supported by Dell EMC.

To report problems or provide feedback https://github.com/dell/OpenManage-PowerShell-Modules/issues

License