-
Notifications
You must be signed in to change notification settings - Fork 383
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Add radiation equivalent dose (#1352)
Added radiation equivalent dose and its two units - Sievert (SI-derived) and Roentgen equivalent man (or, simply, rem). Sievert comes with three prefixes - milli, micro, nano. This will support 99% of usecases, ranging from radiation caused by Earth itself (~6 to 83nSv/h, per this [article](https://www.epa.gov/radnet/about-exposure-and-dose-rates)), [eating bananas](https://en.wikipedia.org/wiki/Banana_equivalent_dose) (yep, that's a real unit), X-rays or tomography scans, as well as measuring health risk of radiation-induced cancer and radiation sickness. Roentgen equivalent man is mostly used in the US, and it can be easily converted to sieverts (1 sievert = 100 rems). It includes only one prefix - milli - as I did not find any sources with other prefixes being used. Wikipedia pages: https://en.wikipedia.org/wiki/Equivalent_dose https://en.wikipedia.org/wiki/Sievert https://en.wikipedia.org/wiki/Roentgen_equivalent_man https://en.wikipedia.org/wiki/Orders_of_magnitude_(radiation) --------- Co-authored-by: Piotr Stenke <[email protected]>
- Loading branch information
1 parent
85aec1b
commit 3b74e19
Showing
18 changed files
with
2,561 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,48 @@ | ||
{ | ||
"Name": "RadiationEquivalentDose", | ||
"BaseUnit": "Sievert", | ||
"XmlDocSummary": "Equivalent dose is a dose quantity representing the stochastic health effects of low levels of ionizing radiation on the human body which represents the probability of radiation-induced cancer and genetic damage.", | ||
"XmlDocsRemarks": "https://en.wikipedia.org/wiki/Equivalent_dose", | ||
"BaseDimensions": { | ||
"L": 2, | ||
"T": -2 | ||
}, | ||
"Units": [ | ||
{ | ||
"SingularName": "Sievert", | ||
"PluralName": "Sieverts", | ||
"FromUnitToBaseFunc": "{x}", | ||
"FromBaseToUnitFunc": "{x}", | ||
"BaseUnits": { | ||
"L": "Meter", | ||
"T": "Second" | ||
}, | ||
"Prefixes": [ "Nano", "Micro", "Milli" ], | ||
"XmlDocSummary": "The sievert is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing radiation, which is defined as the probability of causing radiation-induced cancer and genetic damage.", | ||
"XmlDocRemarks": "https://en.wikipedia.org/wiki/Sievert", | ||
"Localization": [ | ||
{ | ||
"Culture": "en-US", | ||
"Abbreviations": [ "Sv" ] | ||
}, | ||
{ | ||
"Culture": "ru-RU", | ||
"Abbreviations": [ "Зв" ] | ||
} | ||
] | ||
}, | ||
{ | ||
"SingularName": "RoentgenEquivalentMan", | ||
"PluralName": "RoentgensEquivalentMan", | ||
"FromUnitToBaseFunc": "{x} / 100", | ||
"FromBaseToUnitFunc": "{x} * 100", | ||
"Prefixes": [ "Milli" ], | ||
"Localization": [ | ||
{ | ||
"Culture": "en-US", | ||
"Abbreviations": [ "rem" ] | ||
} | ||
] | ||
} | ||
] | ||
} |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
224 changes: 224 additions & 0 deletions
224
UnitsNet.NanoFramework/GeneratedCode/Quantities/RadiationEquivalentDose.g.cs
Some generated files are not rendered by default. Learn more about how customized files appear on GitHub.
Oops, something went wrong.
42 changes: 42 additions & 0 deletions
42
UnitsNet.NanoFramework/GeneratedCode/RadiationEquivalentDose/RadiationEquivalentDose.nfproj
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,42 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<Project ToolsVersion="15.0" DefaultTargets="Build" xmlns="http://schemas.microsoft.com/developer/msbuild/2003"> | ||
<PropertyGroup Label="Globals"> | ||
<NanoFrameworkProjectSystemPath>$(MSBuildExtensionsPath)\nanoFramework\v1.0\</NanoFrameworkProjectSystemPath> | ||
</PropertyGroup> | ||
<Import Project="$(NanoFrameworkProjectSystemPath)NFProjectSystem.Default.props" Condition="Exists('$(NanoFrameworkProjectSystemPath)NFProjectSystem.Default.props')" /> | ||
<PropertyGroup> | ||
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration> | ||
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform> | ||
<ProjectTypeGuids>{11A8DD76-328B-46DF-9F39-F559912D0360};{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}</ProjectTypeGuids> | ||
<ProjectGuid>{dcdccf04-c930-b455-77a4-d9d4a7df8723}</ProjectGuid> | ||
<OutputType>Library</OutputType> | ||
<AppDesignerFolder>Properties</AppDesignerFolder> | ||
<FileAlignment>512</FileAlignment> | ||
<RootNamespace>UnitsNet</RootNamespace> | ||
<AssemblyName>UnitsNet.RadiationEquivalentDose</AssemblyName> | ||
<TargetFrameworkVersion>v1.0</TargetFrameworkVersion> | ||
<DocumentationFile>bin\$(Configuration)\$(AssemblyName).xml</DocumentationFile> | ||
</PropertyGroup> | ||
<Import Project="$(NanoFrameworkProjectSystemPath)NFProjectSystem.props" Condition="Exists('$(NanoFrameworkProjectSystemPath)NFProjectSystem.props')" /> | ||
<ItemGroup> | ||
<Compile Include="..\Quantities\RadiationEquivalentDose.g.cs" /> | ||
<Compile Include="..\Units\RadiationEquivalentDoseUnit.g.cs" /> | ||
<Compile Include="..\Properties\AssemblyInfo.cs" /> | ||
</ItemGroup> | ||
<ItemGroup> | ||
<Reference Include="mscorlib, Version=1.15.6.0, Culture=neutral, PublicKeyToken=c07d481e9758c731"> | ||
<HintPath>..\packages\nanoFramework.CoreLibrary.1.15.5\lib\mscorlib.dll</HintPath> | ||
<Private>True</Private> | ||
<SpecificVersion>True</SpecificVersion> | ||
</Reference> | ||
</ItemGroup> | ||
<ItemGroup> | ||
<None Include="packages.config" /> | ||
</ItemGroup> | ||
<Import Project="$(NanoFrameworkProjectSystemPath)NFProjectSystem.CSharp.targets" Condition="Exists('$(NanoFrameworkProjectSystemPath)NFProjectSystem.CSharp.targets')" /> | ||
<ProjectExtensions> | ||
<ProjectCapabilities> | ||
<ProjectConfigurationsDeclaredAsItems /> | ||
</ProjectCapabilities> | ||
</ProjectExtensions> | ||
</Project> |
26 changes: 26 additions & 0 deletions
26
...neratedCode/RadiationEquivalentDose/UnitsNet.NanoFramework.RadiationEquivalentDose.nuspec
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,26 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<package xmlns="http://schemas.microsoft.com/packaging/2012/06/nuspec.xsd"> | ||
<metadata> | ||
<id>UnitsNet.nanoFramework.RadiationEquivalentDose</id> | ||
<version>5.42.0</version> | ||
<title>Units.NET RadiationEquivalentDose - nanoFramework</title> | ||
<authors>Andreas Gullberg Larsen,nanoframework</authors> | ||
<owners>UnitsNet</owners> | ||
<license type="expression">MIT</license> | ||
<projectUrl>https://github.com/angularsen/UnitsNet</projectUrl> | ||
<requireLicenseAcceptance>false</requireLicenseAcceptance> | ||
<description>Adds RadiationEquivalentDose units for Units.NET on .NET nanoFramework. For .NET or .NET Core, use UnitsNet instead.</description> | ||
<iconUrl>https://raw.githubusercontent.com/angularsen/UnitsNet/ce85185429be345d77eb2ce09c99d59cc9ab8aed/Docs/Images/logo-32.png</iconUrl> | ||
<releaseNotes> | ||
</releaseNotes> | ||
<copyright>Copyright 2013 Andreas Gullberg Larsen ([email protected]).</copyright> | ||
<language>en-US</language> | ||
<tags>nanoframework radiationequivalentdose unit units quantity quantities measurement si metric imperial abbreviation abbreviations convert conversion parse immutable</tags> | ||
<dependencies> | ||
<dependency id="nanoFramework.CoreLibrary" version="1.15.5" /> | ||
</dependencies> | ||
</metadata> | ||
<files> | ||
<file src="..\..\..\Artifacts\UnitsNet.NanoFramework\RadiationEquivalentDose\UnitsNet.*" target="lib" /> | ||
</files> | ||
</package> |
4 changes: 4 additions & 0 deletions
4
UnitsNet.NanoFramework/GeneratedCode/RadiationEquivalentDose/packages.config
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,4 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<packages> | ||
<package id="nanoFramework.CoreLibrary" version="1.15.5" targetFramework="netnanoframework10" /> | ||
</packages> |
Oops, something went wrong.