Notifications
You must be signed in to change notification settings - Fork 3
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Set SGH coupling interval #125
base: develop
Are you sure you want to change the base?
Conversation
Established the initial framework to implement the SGH coupling interval alarm. Not compilable at this point
Introduces a new subroutine to the SGH model that ensures config_adaptive_interval_force_interval divides evenly into config_SGH_coupling_interval
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@alexolinhager , I know you are still working on this PR, but I thought I'd give it a quick review to help keep it moving. I know you are aware of some of these comments already.
@@ -20,7 +20,11 @@ | |||
description="The maximum allowable time step in seconds. If the allowable time step determined by the adaptive CFL calculation is longer than this, then the model will specify config_SGH_max_adaptive_timestep as the time step instead. Defaults to 100 years (in seconds)." | |||
possible_values="Any non-negative real value." | |||
/> | |||
<nml_option name="config_SGH_tangent_slope_calculation" type="character" default_value="from_normal_slope" units="unitless" | |||
<nml_option name="config_SGH_coupling_interval" type="character" default_value="0000-00-00_00:00:01" units="unitless" | |||
description="Time interval at which the SGH model is called by MALI. If set to an interval less than the master timestep, config_SGH_coupling_interval will be superceded by the master timestep. If greater than the master timestep, config_adaptive_timestep_force_interval will be set equal to config_SGH_coupling_interval." |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Rather than modifying config_adaptive_timestep_force_interval
, it might be preferable to throw an error if it's incompatible with the new option. I'm thinking this because config_adaptive_timestep_force_interval
is used for other things too and it might get wonky if some parts of the code or adjusting it.
call mpas_pool_get_array(meshPool, 'simulationStartTime', simulationStartTime) | ||
call mpas_set_time(start_time, dateTimeString=simulationStartTime) | ||
! define SGH coupling interval as a timeInterval type | ||
call mpas_set_timeInterval(coupling_interval, timeString=config_SGH_coupling_interval, ierr=err_tmp) |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
need to retrieve config_SGH_coupling_interval
before using it
!> \details | ||
!> This routine checks that the SGH coupling interval is an even multiple | ||
!> of the adaptive timestep force inverval and divides evenly into the | ||
!> restart interval. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think we settled on not checking the restart interval, because we don't need the SGH coupling interval to divide evenly into the restart interval if we add the effective pressure accumulator fields as restart fields. I realize this comment might be a holdover from where this was copied from, so just flagging this for follow up.
|
||
|
||
|
||
! Check SGH coupling interval is compatible with master timestep and restart interval |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
! Check SGH coupling interval is compatible with master timestep and restart interval | |
! Check SGH coupling interval is compatible with master timestep and timestepping force interval |
do while (associated(block)) | ||
|
||
call mpas_pool_get_subpool(block % structs, 'hydro', hydroPool) | ||
call mpas_pool_get_array(hydroPool, 'effectivePressureSGH', effectivePressureSGH) |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
call mpas_pool_get_array(hydroPool, 'effectivePressureSGH', effectivePressureSGH) | |
call mpas_pool_get_array(hydroPool, 'effectivePressure', effectivePressure) |
785649e
to
727dcd9
Compare
Removes line that sets effectivePressure equal to zero at the start of each timecycle; otherwise, effectivePressure was zero until the very end of the timecycle. Instead, effectivePressure is now initialized to be equal to effectivePressureSGH if there is no effectivePressure field in the input file. A defualt value of -1e36 is given to effectivePressure to flag whether the field is empty at the start of the run.
Establishes
config_SGH_coupling_interval
, the interval at which the SGH model is coupled to the dynamics model. SGH output is then averaged over the coupling interval so that the dynamics model only sees a time-averaged hydrologic state, and not an arbitrary sampling of hydrologic conditions.config_SGH_coupling_interval
must be able to divide evenly intoconfig_dt
orconfig_adaptive_timestep_force_interval
, whichever one is used.