Error 122 description: " The MK2/MK3 did not respond"
Affected systems: All systems with a VE.Bus BMS V2
Bug since Venus v3.41~1 and v3.50~7 (vbdup version v1.13)
introduced by fix for #1325
VictronConnect is also affected.
When updating a Multi/Quattro in a system with a VE.Bus BMS V2 the updater errors out after a time out while waiting for BMS response on a Multi/Quattro only command mistakenly being send to the BMS.
The text was updated successfully, but these errors were encountered:
Error 122 description: " The MK2/MK3 did not respond"
Affected systems: All systems with a VE.Bus BMS V2
Bug since Venus
v3.41~1
andv3.50~7
(vbdup versionv1.13
)introduced by fix for #1325
VictronConnect is also affected.
When updating a Multi/Quattro in a system with a VE.Bus BMS V2 the updater errors out after a time out while waiting for BMS response on a Multi/Quattro only command mistakenly being send to the BMS.
The text was updated successfully, but these errors were encountered: