Skip to content

Latest commit

 

History

History
1489 lines (1093 loc) · 49.3 KB

mqtt.md

File metadata and controls

1489 lines (1093 loc) · 49.3 KB

Overview

The system is designed to accept several types of MQTT commands as inputs and publish several types of MQTT packets as outputs. Inputs can be management commands or state changes. Outputs will be state change notifications.

Management commands are commands that manage the state of the system like modifying the all link database on a device and in general, won't be needed that often. Management commands have a fixed MQTT topic (set in configuration file input cmd_topic) and fixed JSON payload format.

State changes can be inputs to the devices in the network (e.g. turn a light off, set a dimmer to 50%) or outputs from the system as notifications (e.g. motion sensor triggered, light is now at 50%). State change command and notification topics and payloads are totally configurable. Each device type in the configuration file has a topic and payload template that allows you to customize how state changes are input and output from the system.

Addressing

The Insteon six digit hex code address of a device is it's identifier. An optional name (set in the config file) can also be used. MQTT topics are case sensitive so all Insteon hex addresses must be entered in lower case format (e.g. "a1.b2.c3", not "A1.B2.B3"). The modem can be identified by it's address or the string "modem".

Required Device Initialization

See device initialization for a discussion about the steps required when setting up a new or factory reset device.

Management commands

Management commands can be sent by using the command line tool "insteon-mqtt" or by publishing a MQTT message to the command topic (cmd_topic in the config file). Management commands may be supported by the modem, by the devices, or by both. For examples of the command style, see command line module source code.

All management commands use a payload that is a JSON dictionary. In the documentation below, if a key/value pair is enclosed in square brackets [], then it's optional. If a value can be one of many like true or false, then the possible values are separated by a slash /.

The MQTT topic to publish management commands to is (aa.bb.cc is the example device address):

insteon/command/aa.bb.cc

Alternatively you can use the nice names from the config.yaml file too:

insteon/command/NICE NAME

Print the Version of Insteon-MQTT

Supported: modem

If requesting help or submitting a bug, you can use this command to get the version of Insteon-MQTT that you are running:

The default topic location is:

insteon/command/modem

{ "cmd" : "version"}

This command can also be run from the command line:

insteon-mqtt -v

Join a New Device to the Network

Supported: devices

See initialization for a discussion of join.

Join all devices

Supported: modem

See initialization for a discussion of join-all.

Pair a Device to the Modem

Supported: devices

See initialization for a discussion of pair.

Pair all devices

Supported: modem

See initialization for a discussion of pair-all.

Sync Device Links

Supported: modem, device

See scenes for a detailed description of sync.

Sync All Device Links

Supported: modem

See scenes for a detailed description of sync_all.

Import Device Links

Supported: modem, device

See scenes for a detailed description of import_scenes.

Import All Device Links

Supported: modem

See scenes for a detailed description of import_scenes_all.

Activate all linking mode

Supported: modem, devices

This turns on all linking mode and is the same as pressing the set button for 3 sec on the modem or device. The default group is 1.

This command is not normally needed by most users. However, if you are experiencing difficulty with the 'join' or 'pair' commands, this command can be used to solve those issues.

For example, this can be used in place of the 'join' command. To do this use the linking command in place of physically pressing the set button on the device. So first run 'linking modem', then second run 'linking aa.bb.cc' to setup a link to control the device from the modem.

Similarly, this can also be used in place of the 'pair' command. To do this first run 'linking aa.bb.cc', then run 'linking modem' to make the device a controller of the modem so the modem will get state change messages from the device. For more complicated devices, you can also link the other groups on the device as well.

The command payload is:

{ "cmd" : "linking", ["group" : group] }

Once you run the linking command, you should also run 'refresh' on the device to update it's local database. The modem will automatically update, but the devices don't send a message when the linking is complete so there is no way to know when to update the database.

Refresh the device state and download it's all link database

Supported: modem, devices

See initialization for a discussion of refresh.

Refresh all devices

Supported: modem

See initialization for a discussion of refresh-all.

Get device model information

Supported: device

Will send a command to the device to get the device category, sub-category, and firmware version. This information may be used to determine what features are available on the device:

{ "cmd" : "get_model" }

Get device engine information

Supported: device

The engine version can be i1, i2, or i2cs. The engine version defines what type of messages can be used with a device and the type of all link database used by a device.

New Insteon devices purchased after 2018 are almost certainly all i2cs devices. By default, we assume a device is i2cs.

If you have an older device that is not responding the the refresh command try running get_engine and then try running refresh again. This only needs to be run once on any device. The resulting information will be saved in the device data.

{ "cmd" : "get_engine" }

Get all device engines

Supported: modem

This will cause a get_engine command to be sent to each device (i.e. devices defined in the config file). The command payload is:

{ "cmd" : "get_engine_all"}

Add the device as a controller of another device.

Supported: modem, devices

This commands modifies the all link database on the device to add it as a controller of another device. If the two-way flag is set (true is the default), it will also modify the other device database to have an entry as the responder of the first device. There is a group input (1-255) of the Insteon group number to use for the each end. The controller group is the button being pressed. The responder group is the button that should respond. The command payload is:

{ "cmd" : "db_add_ctrl_of", "local_group" : ctrl_group,
  remote_addr" : aa.bb.cc, "remote_group" : resp_group,
  ["two_way" : true/false], [refresh" : true/false],
  ["local_data" : [D1,D2,D3]], ["remote_data" : [D1, D2,D3]] } }

Add the device as a responder of another device.

Supported: modem, devices

This commands modifies the all link database on the device to add it as a responder of another device. If the two-way flag is set (true is the default), it will also modify the other device database to have an entry as the controller of the first device. There is a group input (1-255) of the Insteon group number to use for the each end. The controller group is the button being pressed. The responder group is the button that should respond. The command payload is:

{ "cmd" : "db_add_resp_of", "local_group" : resp_group,
  remote_addr" : aa.bb.cc, "remote_group" : ctrl_group,
  ["two_way" : true/false], [refresh" : true/false],
  ["local_data" : [D1,D2,D3]], ["remote_data" : [D1, D2,D3]] } }

Delete the device as a controller of another device.

Supported: modem, devices

This commands modifies the all link database on the device to remove it as a controller of another device. If the two-way flag is set (true is the default), it will also modify the other device database to remove the entry as the responder of the first device. The group is an integer (1-255) of the Insteon group number to use for the link. The command payload is:

{ "cmd" : "db_del_ctrl_of", "addr" : aa.bb.cc, "group" : group,
  ["two_way" : true/false], [refresh" : true/false] }

Delete the device as a responder of another device.

Supported: modem, devices

This commands modifies the all link database on the device to remove it as a responder of another device. If the two-way flag is set (true is the default), it will also modify the other device database to remove the entry as the controller of the first device. The group is an integer (1-255) of the Insteon group number to use for the link. The command payload is:

{ "cmd" : "db_del_resp_of", "addr" : aa.bb.cc, "group" : group,
  ["two_way" : true/false], [refresh" : true/false] }

Change KeypadLinc button LED state.

Supported: KeypadLinc

This command turns the LED on a KeypadLinc button on or off. This also toggles the internal state of the button. So if a button LED is turned off, the next click of the button will send out an ON command (and vice verse). Button is an integer in the range [1,8]. In the 6 button version, buttons 1,2 and 7,8 are not commandable and can only be toggled by sending on/off commands.

{ "cmd": "set_button_led", "group" : button, "is_on" : true/false }

Get and set operating flags.

Supported: devices, modem (get_flags only)

To request the current flag settings on a device:

insteon-mqtt config.yaml get-flags aa.bb.cc

The MQTT format of the command is:

{ "cmd" : "get_flags"}

This command gets and sets various Insteon device flags. The set of supported flags depends on the device type. The command line tool accepts an arbitrary list of "key=value" strings which get sent to the device for validation. For example, to change the back light level of a switch:

insteon-mqtt config.yaml set-flags aa.bb.cc backlight=0x11

The MQTT format of the command is:

{ "cmd" : "set_flags", "KEY" : "VALUE", ... }

Switch, KeypadLinc, and Dimmer all support the flags:

  • backlight: changes the LED backlight level on the device. Insteon documentation defines the range from 0x11 - 0x7F, however, levels below 0x11 appear to work on some devices, and levels above 0x7F may also work. Switches and dimmers go as low as 0x04 and KeypadLincs go all the way down to 0x01. Setting to 0x00 will turn off the backlight, any other value will turn on the backlight.
  • on_level: integer in the range 0x00-0xff which sets the on level that will be used when the button is pressed.
  • load_attached: 0/1 to attach or detach the load from the group 1 button.
  • follow_mask: 8 bit integer flags - 1 per button. Requires a group=N input as well. This sets the follow mask for the input group. When that button is pressed, any button with the bit set in this mask will be changed to match the state of the button. This is used for the 6 button device to have the groups (1,2) and (7,8) stay in sync.
  • off_mask: 8 bit integer flags - 1 per button. Requires a group=N input as well. This sets the off mask for the input group. When that button is pressed, all the buttons with the bits set in this mask will turn off. This is used to implement radio buttons.
  • signal_bits: 8 bit integer flags - 1 per button. Only used for non-toggle buttons. If a bit is 1, then the button only sends on commands. If a bit is 0, then the button only sends off commands.
  • nontoggle_bits: 8 bit integer flags - 1 per button. If a bit is 1, then that button is a non-toggle button and will only send a signal per the signal_bits input. If a bit is 0, then that button is a toggle button and will alternate on an doff signals

KeypadLinc and Dimmer support the flags:

  • ramp_rate: float in the range of 0.5 to 540 seconds which sets the default ramp rate that will be used when the button is pressed
  • resume_dim: bool indicating if the device's on level should be determined from the configured on_level flag, or based on the last on level (currently this will only effect manually pressing the button and not commands send through insteon-mqtt)

IOLinc supports the flags:

  • mode: "latching" / "momentary-a" / "momentary-b" / "momentary-c" to change the relay mode (see the IOLinc user's guide for details)
  • trigger_reverse: 0/1 reverses the trigger command state
  • relay_linked: 0/1 links the relay to the sensor value
  • momentary_secs: .1-6300 the number of seconds the relay stays closed in momentary mode. There is finer resolution at the low end. Higher values will be rounded to the next valid value. Setting this to 0 will cause the IOLinc to change to latching mode. Setting this to a non-zero value will cause the IOLinc to change to momentary mode.

Motion Sensors support the flags:

  • led_on: 0/1 - Should led on the device flash on motion?

  • night_only: 0/1 - Should motion only be reported at night?

  • on_only: 0/1 - Should only on motions be reported with no off messages?

  • timeout: seconds between state updates (30 second increments, 2842 models allow between 30 seconds to 4 hours, the 2844 models allow between 30 seconds and 40 minutes).

  • light_sensitivity: 1-255: Amount of darkness required for night to be triggered. Affects night_only mode as well as the dawn/dusk reporting

Print the current all link database.

Supported: modem, devices

This command is mainly used from the command line tool and allows printing of the current all link database for a device.

{ "cmd": "print_db" }

Scene triggering.

Supported: devices

This command triggers scenes from a device, as though the button on the device has been pressed. The group is the button number and this will simulate pressing the button on the device. This will cause all linked responders to react to the ON/OFF command. The reason field is optional and will be passed through to the output state change payload, see reason.

Args:

  • group = Will default to 1 and can generally be omitted for most devices.

  • is_on = True or False. This defines whether linked devices are sent an on or an off command. The target device will treat off as level = 0x00 and on as the level defined on the device on_level unless level is passed.

  • level = If present, the target device will change to this on_level

  • reason = Will be passed through to the output state, defaults to 'device' See reason

    { "cmd": "scene", "group" : group, "is_on" : 0/1, ["level": 0-255],
    ["reason" : "..."] }
    

Supported: modem

For the modem, this triggers virtual modem scenes (i.e. any group number where the modem is the controller). The modem also allows the triggering of scenes from a name defined in a Scene Management file as well. To access a scene by its name simply drop the group attribute and add the name attribute such as.

Args:

  • Same as the device args, but modem does not support the level command
{ "cmd": "scene", "name" : "test_scene", "is_on" : 0/1, ["reason" : "..."] }

Mark a battery device as awake.

Supported: battery devices only

Please see Battery Devices for information about the awake command.

Force a Battery Voltage Check

Supported: Remote and Motion only

The next time the device is awake, this will send a request for the battery voltage. If it is low, it will trigger an event on the low_voltage topic.

{ "cmd": "get_battery_voltage" }
  ```


### Set the Low Battery Voltage

Supported: Motion only

Sets the value at which the battery in the device will be determined to be
low.  Only used on devices that support battery voltage checks and have
removable batteries.  Which is currently only the Motion sensor.  The default
low battery voltage for the motion sensor is 7.0.  The normal low voltage
message would have been sent on group 3 when this voltage is reached anyways.

This is useful for those of us using Li-Ion batteries in the motion sensors
which have an initial voltage of 7.8 at best, and a low voltage well below
that of a normal alkaline battery.  When using these batteries, the low
voltage message on group 3 is likely never sent, because the battery is always
below the expected value

{ "cmd": "set_low_battery_voltage", "voltage": 7.0 } ```

Send a raw insteon command.

Supported: devices

Send a raw insteon command to devices. Any changes as a result of this command won't be kept in sync automatically, so use this at your risk. This command is intended to help developing and debugging insteon-mqtt, and is as low level as it gets. It supports standard and extended direct messages.

Standard Direct message payload

A standard message requires the cmd1 and cmd2 attributes - allowed values are 0x00 (0) -> 0xFF (255).

{ "cmd": "raw_command", "cmd1": 31, "cmd2": 0 }

Extended Direct message payload

To send an extended message, simply provide the data property (a list of numbers). It's value will be right padded with 0s and trimmed to 14 digits, then converted to bytes. The allowed values cmd1, cmd2, and elements within the data array are 0x00 (0) -> 0xFF (255). The payload also allows specifying the crc type, with the allowed values of D14, CRC. If the type is not supplied the data array will be sent as is without calculating a CRC.

{ "cmd": "raw_command", "cmd1": 32, "cmd2": 4, data: [], crc_type: "D14" }

Insteon command tables

You can find insteon command tables online; however, they are usually out dated. Most modern devices (since ~2012) run the i2cs engine, which is an extension on the i2 engine and updated certain commands to require the D14 crc. If you try commands from an old command table and recieve a response that indicates an invalid checksum for a standard command, you can try it as an extended command with the D14 checksum.


State change commands

State change commands can be sent by using the command line tool "insteon-mqtt" or by publishing a MQTT message to the specific command topic for a device as set in the configuration file. Devices will publish state changes using the state topic set in the configuration file and using the format as defined by the payload templates.

The templates are defined using the Jinja2 package. Each define (and command) defines a set of variables that are available for you to use in the templates. So there are no real pre-defined topics and payloads - they are all customizable.

The sample configuration file provided is designed to work with Home Assistant and contains templates and examples for using it with that system. In the future, other example configurations may also be provided (feel free to send me any).

MQTT topic templates have the following template variables available for use. These variables are also available for the payload templates.

  • 'address' is the Insteon hex code address (a1.b2.c3).
  • 'name' is the name set in the config file or address if none was set.

The input state change payload template must convert the inbound payload into the format that the device expects.


Switches

On/off switches will publish their on/off state on the state topic whenever the device state changes. Switches have only two states: on and off.

Output state change messages have the following variables defined which can be used in the templates:

  • 'on' is 1 if the device is on and 0 if the device is off.
  • 'on_str' is "on" if the device is on and "off" if the device is off.
  • 'mode' is the on/off mode: 'normal', 'fast', or instant'
  • 'fast' is 1 if the mode is fast, 0 otherwise
  • 'instant' is 1 if the mode is instant, 0 otherwise
  • 'reason' is the reason for the change. See reason

Manual state output is invoked when a button on the device is held down. Manual mode flags are UP or DOWN (when the on or off button is pressed and held), and STOP (when the button is released. Manual template variables are name, address, and:

  • 'manual_str' = 'up'/'off'/'down'
  • 'manual' = 1/0/-1
  • 'manual_openhab' = 2/1/0

Input state change messages have the following variables defined which can be used in the templates:

  • 'value' is the message payload (string)
  • 'json' is the message payload converted to JSON format if the conversion succeeds. Values inside the JSON payload can be accessed using the form 'json.ATTR'. See the Jinja2 docs for more details.

The input state change payload template must convert the input message into the format. The optional mode flag can be used to send a 'normal' (default)', 'fast', or 'instant' command to the device.

{ "cmd" : "on"/"off", ["mode" : 'normal'/'fast'/'instant'] }

The input command can be either a direct on/off command which will just change the load connected to the switch (using the on_off inputs) or a scene on/off command which simulates pressing the button on the switch (using the scene inputs).

Here is a sample configuration that accepts and publishes messages using upper case ON an OFF payloads.

switch:
  # Output state change:
  state_topic: 'insteon/{{address}}/state'
  state_payload: '{{on_str}}'

  manual_state_topic: 'insteon/{{address}}/manual_state'
  manual_state_payload: '{{manual_str.upper()}}'

  # Direct change only changes the load:
  on_off_topic: 'insteon/{{address}}/set'
  on_off_payload: '{ "cmd" : "{{value.lower()}}" }'

  # Scene change simulates clicking the switch:
  scene_topic: 'insteon/{{address}}/scene'
  scene_payload: '{ "cmd" : "{{value.lower()}}" }'

When the switch changes state a message like ON or OFF is published to the topic insteon/a1.b1.c1/state. To command the switch to turn on, send a message to insteon/a1.b1.c1/set with the payload ON.


Dimmers

Dimmers are the same as switches but have an addition field "level" which sets the dimming level using the range 0->255 (0 is the same as off and 255 is 100% on). They will publish their on/off state on the state topic whenever the device state changes.

Output state change messages have the following variables defined which can be used in the templates:

  • 'on' is 1 if the device is on and 0 if the device is off.
  • 'on_str' is "on" if the device is on and "off" if the device is off.
  • 'level_255' is the dimmer level in the range 0->255.
  • 'level_100' is the dimmer level in the range 0->100.
  • 'mode' is the on/off mode: 'normal', 'fast', or instant'
  • 'fast' is 1 if the mode is fast, 0 otherwise
  • 'instant' is 1 if the mode is instant, 0 otherwise
  • 'reason' is the reason for the change. See reason

Manual state output is invoked when a button on the device is held down. Manual mode flags are UP or DOWN (when the on or off button is pressed and held), and STOP (when the button is released. Manual template variables are name, address, and:

  • 'manual_str' = 'up'/'off'/'down'
  • 'manual' = 1/0/-1
  • 'manual_openhab' = 2/1/0

Input state change messages have the following variables defined which can be used in the templates:

  • 'value' is the message payload (string)
  • 'json' is the message payload converted to JSON format if the conversion succeeds. Values inside the JSON payload can be accessed using the form 'json.ATTR'. See the Jinja2 docs for more details.

The input state change has two inputs. One is the same as the switch input system and only accepts on and off states in either direct or scene mode. The second is similar but also accepts the level argument to set the dimmer level. The dimmer payload template must convert the input message into the format (LEVEL must be in the range 0->255). The optional mode flag can be used to send a 'normal' (default)', 'fast', or 'instant' command to the device.

{ "cmd" : "on"/"off", "level" : LEVEL, ["mode" : 'normal'/'fast'/'instant'] }

Here is a sample configuration that accepts and publishes messages using a JSON format that contains the level using the tag "brightness".

dimmer:
  # Output state change:
  state_topic: 'insteon/{{address}}/state'
  state_payload: '{ "state" : "{{on_str}}", "brightness" : {{level_255}} }'

  manual_state_topic: 'insteon/{{address}}/manual_state'
  manual_state_payload: '{{manual_str.upper()}}'

  # Input state change for the load:
  on_off_topic: 'insteon/{{address}}/set'
  on_off_payload: '{ "cmd" : "{{json.state}}" }'

  # Scene change simulates clicking the switch:
  scene_topic: 'insteon/{{address}}/scene'
  scene_payload: '{ "cmd" : "{{value.lower()}}" }'

  # Dimming control:
  level_topic: 'insteon/{{address}}/level'
  level_payload: >
     { "cmd" : "{{json.state}}",
       "level" : {{json.brightness}} }

To change the level of the dimmer with this configuration, publish a message like this to the level topic for the device:

{ "state" : "on", "brightness" : 175 }

FanLinc

A FanLinc device is an Insteon device for controlling a ceiling fan and light. The light portion of the FanLinc uses the dimmer settings (see above). The fan controller uses a four speed setting system (off, low, medium, and high).

The fan portion of the device can be turned on and off (where on means use the last speed setting that was chosen) or set to a specific level.

Output state change messages have the following variables defined which can be used in the templates:

  • 'on' is 1 if the device is on and 0 if the device is off.
  • 'on_str' is "on" if the device is on and "off" if the device is off.
  • 'level' is the integer speed level 0-3 for off (0), low (1), medium (2), and high (3)
  • 'level_str' is the speed level 'off', 'low', 'medium', or 'high'.
  • 'reason' is the reason for the change. See reason

Input state change messages have the following variables defined which can be used in the templates:

  • 'value' is the message payload (string)
  • 'json' is the message payload converted to JSON format if the conversion succeeds. Values inside the JSON payload can be accessed using the form 'json.ATTR'. See the Jinja2 docs for more details.

The input state change has two inputs. One is the same as the switch input system and only accepts on and off states. The second is similar but also accepts the level argument to set the fan speed. The speed payload template must convert the input message into the format (SPEED must be one of the valid level integers or strings).

{ "cmd" : "on"/"off" }
{ "cmd" : SPEED }

Here is a sample configuration. HomeAssistant starting in version 2021.4.0 dropped support for the off/low/medium/high fan speeds. See config-example.yaml in the mqtt -> fan section for an example HomeAssistant config that works with InsteonMQTT.

fan_linc:
  # Output state change:
  fan_state_topic: 'insteon/{{address}}/fan/state'
  fan_state_payload: '{{on_str}}'

  # Input on/off change (payload should be 'ON' or 'OFF')
  fan_on_off_topic: 'insteon/{{address}}/fan/set'
  fan_on_off_payload: '{ "cmd" : "{{value.lower}}" }'

  # Output speed state change.
  fan_speed_topic: 'insteon/{{address}}/fan/speed/state'
  fan_speed_payload: '{{level_str}}'

  # Input fan speed change (payload should be 'off', 'low', 'medium',
  # or 'high'.
  fan_speed_set_topic: 'insteon/{{address}}/fan/speed/set'
  fan_speed_set_payload: '{ "cmd" : "{{value.lower}}" }'

KeypadLinc

The KeypadLinc is a wall mounted on/off or dimmer control and scene controller. Basically it combines a on/off or dimmer switch and remote control. Dimmers and on/off devices are listed under separate entries in the input config file which controls the behavior of the group 1 switch. The other buttons are treated as on/off switches (see the switch documentation above) but have no load connected to them. KeypadLincs are usually configured as 6 button or 8 button devices with the following button number layouts:

   6 button         8 button
   ---------        --------
     1 on           1      2
   3       4        3      4
   5       6        5      6
     1 off          7      8

The button change defines the following variables for templates:

  • 'button' is 1...n for the button number.
  • 'on' is 1 if the button is on, 0 if it's off.
  • 'on_str' is 'on' if the button is on, 'off' if it's off.
  • 'mode' is the on/off mode: 'normal', 'fast', instant', or 'ramp'
  • 'fast' is 1 if the mode is fast, 0 otherwise
  • 'instant' is 1 if the mode is instant, 0 otherwise
  • 'transition' is the ramp rate in seconds.
  • 'reason' is the reason for the change. See reason

The optional transition flag can be used to specify a ramp rate. If 'ramp' mode is specified but no transition value, a ramp rate of 2 seconds is used. If a transition value is specified but no mode, 'ramp' mode is implied. Ramp mode is only supported on 2334-222 and 2334-232 devices at this time.

{ "cmd" : "on"/"off", "level" : LEVEL, ["mode" : 'normal'/'fast'/'instant'/'ramp'], "transition" : RATE }

Note: RATE is specified as a number of seconds and is rounded down to the nearest supported Half Rate. Note that not all devices support ramp rates and that specifying one will limit the precision of LEVEL. See http://www.madreporite.com/insteon/ramprate.htm for more details on the "Light ON at Ramp Rate" and "Light OFF at Ramp Rate" commands.

Manual state output is invoked when a button on the device is held down. Manual mode flags are UP or DOWN (when the on or off button is pressed and held), and STOP (when the button is released. Manual template variables are name, address, and:

  • 'manual_str' = 'up'/'off'/'down'
  • 'manual' = 1/0/-1
  • 'manual_openhab' = 2/1/0
  • 'reason' See reason

A sample remote control topic and payload configuration is:

keypad_linc:
  # Output on/off state change:
  btn_state_topic: 'insteon/{{address}}/state/{{button}}'
  btn_state_payload: '{{on_str.upper()}}'

  # Output dimmer state changes.
  dimmer_state_topic: 'insteon/{{address}}/state/1'
  state_payload: '{ "state" : "{{on_str}}", "brightness" : {{level_255}} }'

  manual_state_topic: 'insteon/{{address}}/manual_state/{{button}}'
  manual_state_payload: '{{manual_str.upper()}}'

  # Input on/off state change.  For any button besides 1, this just
  # updates the LED state.
  btn_on_off_topic: 'insteon/{{address}}/set/{{button}}'
  btn_on_off_payload: '{ "cmd" : "{{json.state}}" }'

  # Input dimmer control
  level_topic: 'insteon/{{address}}/set/1'
  level_payload: >
     { "cmd" : "{{json.state}}",
       "level" : {{json.brightness}} }

  # Scene input - simulates clicking the button.
  btn_scene_topic: 'insteon/{{address}}/scene/{{button}}'
  btn_scene_payload: '{ "cmd" : "{{value.lower()}}" }'

Battery Sensors

Battery powered sensors (which include door sensors, hidden door sensors, and window sensors) do not accept any input commands. Internally, they will send state changes on the Insteon groups 1 for motion and 3 for low battery. Each of these messages only has two states, on or off.

The battery powered sensor sends motion events on the "state" configuration topic which defines the following variables defined which can be used in the templates:

  • 'on' is 1 if the device is on and 0 if the device is off.
  • 'on_str' is "on" if the device is on and "off" if the device is off.

The low battery condition defines the following variables for templates:

  • 'is_low' is 1 for a low battery, 0 for normal.
  • 'is_low_str' is 'on' for a low battery, 'off' for normal.

Some battery sensors also issues a heartbeat every 24 hours that can be used to confirm that they are still working. Presently, only the Leak sensor is known to use heartbeat messages. The following variables can be used for templates:

  • "is_heartbeat" is 1 whenever a heartbeat occurs
  • "is_heartbeat_str" is "on" whenever a heartbeat occurs
  • "heartbeat_time" is the Unix timestamp of when the heartbeat occurred

The Battery Sensor class is also the base for other battery devices that have additional features, namely Motion Sensors, Leak Sensors, and Remotes.

A sample battery sensor topic and payload configuration is:

battery_sensor:
  # Trigger events
  state_topic: 'insteon/{{address}}/state'
  state_payload: '{{on_str.upper()}}'

  # Low battery warning
  low_battery_topic: 'insteon/{{address}}/battery'
  low_battery_payload: '{{is_low_str.upper()}}'

  # Heartbeats
  heartbeat_topic: 'insteon/{{address}}/heartbeat'
  heartbeat_payload: '{{heartbeat_time}}'

Motion Sensors

Motion sensors do not accept any input commands. The motion triggering and low battery are inherited from the battery sensor inputs. The motion sensors adds another possible state change for dawn/dusk (Insteon group 2)

The dawn/dusk change defines the following variables for templates:

  • 'is_dawn' is 1 for dawn, 0 for dusk
  • 'is_dawn_str' is "on" for dawn, "off" for dusk
  • 'is_dusk' is 1 for dusk, 0 for dawn
  • 'is_dusk_str' is "on" for dusk, "off" for dawn
  • 'state' is "dawn" or "dusk"

A sample motion sensor topic and payload configuration is:

motion:
  # Light level events
  dawn_dusk_topic: 'insteon/{{address}}/dawn'
  dawn_dusk_payload: '{{is_dawn_str.upper()}}'

Hidden Door Sensors

Hidden Door sensors do not accept any input commands in their normal "off" state. If you press and hold the link button for about 3 seconds it will beep and its small LED will blink. It will be awake for about the next 4 minutes where you can download the db and or configure the units many options. All configuration option offered by this device are available for configuration here. The open/closed (one group) and low battery are inherited from the battery sensor inputs. The hidden door sensor adds another possible state change the 2 groups configuration where it will report open as ON on group 0x01 and closed as ON on group 0x02. The raw Insteon reported battery voltage level is reported over MQTT.

Note: The Insteon Dev notes provide 4 points for correlation of this raw battery level to actual battery voltages.

61=~1.75V 54=~1.6V 51=~1.5V 40=~1.25V (default low battery mark)

The following variable is available for templating:

'batt_volt' is the raw Insteon voltage level

A sample hidden door sensor topic and payload configuration is:

hidden_door:
  battery_voltage_topic: 'insteon/{{address}}/battery_voltage'
  battery_voltage_payload: '{"voltage" : {{batt_volt}}}'

To set configuration option on the device, first press and hold the device link button until it beeps and the LED starts flashing. Next tell insteon-mqtt the device is awake with:

{ "cmd" : "awake" }

This will tell insteon-mqtt to send commands right away rather than queuing until the deice is awake.

View Current configuration in log:

{ "cmd" : "get_flags" }

This configuration can be changed with the following command:

{ "cmd" : "set_flags", "key" : value }

An example to turn on two groups:

{ "cmd" : "set_flags", "two_groups" : 1 }'

Configuration is available for the following options:

The following key/value pairs are available:

  • cleanup_report = 1/0: tell the device whether or not to send cleanup reports

  • led_disable = 1/0: disables small led on back of device to blink on state change

  • link_to_all = 1/0: links to 0xFF group (all available groups)

  • two_groups = 1/0: Report open/close on group 1 or report open on group 1 and closed on 2

  • prog_lock = 1/0: prevents device from being programmed by local button presses

  • repeat_closed = 1/0: Repeat open command every 5 mins for 50 mins

  • repeat_open = 1/0: Repeat open command every 5 mins for 50 mins

  • stay_awake = 1/0: keeps device awake - but uses a lot of battery

Beyond these flags there are two additional settings:

  • Low Battery threshold. This is the raw Insteon voltage level that where the device will trigger a group 0x03 low battery warning. Example to set to 64 below:
{ "cmd" : "set_low_battery_voltage", "voltage" : 64 }
  • Heart Beat Interval. The sensor will send a heartbeat to prove that it is functional at a configurable interval. The more frequent it wakes up to this group 0x04 message the faster the battery will deplete. The time between heartbeats sent is 5 minutes x this setting. So setting this value to 24 would be 24 x 5 mins = 120 mins. this can be set from 0 -> 255. Setting to 0 = 24 hours or 1440 minutes. Example: to set to 10 minutes below:
{ "cmd" : "set_heart_beat_interval", "interval" : 2 }

Leak Sensors

Leak sensors do not accept any input commands. The leak sensor has state change for wet/dry events and also for heartbeat every 24 hours. The leak sensors does not report low battery condition like other battery operated devices.

The wet/dry change defines the following variables for templates:

  • 'is_wet' is 0 for dry, 1 for wet
  • 'is_wet_str' is 'on' for wet, 'off' for dry
  • 'is_dry' is 0 for wet, 1 for dry
  • 'is_dry_str' is 'on' for dry, 'off' for wet
  • 'state' is 'wet' or 'dry'

A sample leak sensor topic and payload configuration is:

leak:
  wet_dry_topic: 'insteon/{{address}}/wet'
  wet_dry_payload: '{{state.upper()}}'

Remote Controls

Remote controls are battery powered scene controllers. They do not accept any input commands. The low battery messages are inherited from the battery sensor inputs. The remote adds another state change for button on and off events. Buttons on the remote alternate sending on and off commands each time they are pressed.

The button change defines the following variables for templates:

  • 'button' is 1...n for the button number.
  • 'on' is 1 if the button is on, 0 if it's off.
  • 'on_str' is 'on' if the button is on, 'off' if it's off.
  • 'mode' is the on/off mode: 'normal', 'fast', or instant'
  • 'fast' is 1 if the mode is fast, 0 otherwise
  • 'instant' is 1 if the mode is instant, 0 otherwise

Manual state output is invoked when a button on the device is held down. Manual mode flags are UP or DOWN (when the on or off button is pressed and held), and STOP (when the button is released. Manual template variables are name, address, and:

  • 'manual_str' = 'up'/'off'/'down'
  • 'manual' = 1/0/-1
  • 'manual_openhab' = 2/1/0

A sample remote control topic and payload configuration is:

remote:
  state_topic: 'insteon/{{address}}/state/{{button}}'
  state_payload: '{{on_str.upper()}}'

  manual_state_topic: 'insteon/{{address}}/manual_state/{{button}}'
  manual_state_payload: '{{manual_str.upper()}}'

Smoke Bridge

A smoke bridge device does not accept any input commands. Internally, they send updates for a number of groups depending on the type of alert and a single clear group to say everything is OK. The system will translate those into one of four output MQTT messages (smoke detected, CO warning, low battery, and a general error). When the clear message is received internally, an off state is sent to each of the four topics.

The smoke bridge defines the following template variables for all of the alerts:

  • 'on' is 1 if the alert is active, 0 if it's not
  • 'on_str' is 'on' if the alert is active, 'off' if it's not

A sample smoke bridge topic and payload configuration is:

smoke_bridge:
  smoke_topic: 'insteon/{{address}}/smoke'
  smoke_payload: '{{on_str.upper()}}'

  co_topic: 'insteon/{{address}}/co'
  co_payload: '{{on_str.upper()}}'

  battery_topic: 'insteon/{{address}}/battery'
  battery_payload: '{{on_str.upper()}}'

  error_topic: 'insteon/{{address}}/error'
  error_payload: '{{on_str.upper()}}'

Outlets

On/off outlets will publish their on/off state on the state topic whenever the device state changes. Outlets have only two states: on and off and use group 1 for the top outlet and group 2 for the bottom outlet.

Output state change messages have the following variables defined which can be used in the templates:

  • 'on' is 1 if the device is on and 0 if the device is off.
  • 'on_str' is "on" if the device is on and "off" if the device is off.
  • 'button' is 1 or 2 for the button number.
  • 'mode' is the on/off mode: 'normal', 'fast', or instant'
  • 'fast' is 1 if the mode is fast, 0 otherwise
  • 'instant' is 1 if the mode is instant, 0 otherwise
  • 'reason' is the reason for the change. See reason

Input state change messages have the following variables defined which can be used in the templates:

  • 'value' is the message payload (string)
  • 'json' is the message payload converted to JSON format if the conversion succeeds. Values inside the JSON payload can be accessed using the form 'json.ATTR'. See the Jinja2 docs for more details.

The input state change payload template must convert the input message into the format. The optional mode flag can be used to send a 'normal' (default)', 'fast', or 'instant' command to the device.

{ "cmd" : "on"/"off", "group" : group, ["mode" : 'normal'/'fast'/'instant'] }

The input command can be either a direct on/off command which will just change the load connected to the switch (using the on_off inputs) or a scene on/off command which simulates pressing the button on the switch (using the scene inputs).

Here is a sample configuration that accepts and publishes messages using upper case ON an OFF payloads.

outlet:
   # Output state change:
   state_topic: 'insteon/{{address}}/state/{{button}}'
   state_payload: '{{on_str}}'

   # Direct change only changes the load:
   on_off_topic: 'insteon/{{address}}/set/{{button}}'
   on_off_payload: '{ "cmd" : "{{value.lower()}}" }'

   # Scene change simulates clicking the switch:
   scene_topic: 'insteon/{{address}}/scene/{{button}}'
   scene_payload: '{ "cmd" : "{{value.lower()}}" }'

When the outlet changes state a message like ON or OFF is published to the topic insteon/a1.b1.c1/state/1. To command the switch to turn on, send a message to insteon/a1.b1.c1/set/1 with the payload ON.


Thermostat

The thermostat has a lot of available states and commands.

Output state change topic and payload. Available variables for templating in all cases are: address = 'aa.bb.cc' name = 'device name'

State Topics

The following is an example configuration:

temp_c = temperature in celsius temp_f = temperature in farenheit

ambient_temp_topic: 'insteon/{{address}}/ambient_temp'
ambient_temp_payload: ''{"temp_f" : {{temp_f}}, "temp_c" : {{temp_c}}}''
cool_sp_state_topic: 'insteon/{{address}}/cool_sp_state'
cool_sp_state_payload: ''{"temp_f" : {{temp_f}}, "temp_c" : {{temp_c}}}''
heat_sp_state_topic: 'insteon/{{address}}/heat_sp_state'
heat_sp_state_payload: ''{"temp_f" : {{temp_f}}, "temp_c" : {{temp_c}}}''

fan_mode = "ON", "AUTO" is_fan_on = 0/1

fan_state_topic: 'insteon/{{address}}/fan_state'
fan_state_payload: '{{fan_mode}}'

mode = 'OFF', 'AUTO', 'HEAT', 'COOL', 'PROGRAM'

mode_state_topic: 'insteon/{{address}}/mode_state'
mode_state_payload: '{{mode}}'

humid = humidity percentage

humid_state_topic: 'insteon/{{address}}/humid_state'
humid_state_payload: ''{{humid}}''

status = "OFF", "HEATING", "COOLING" is_heating = 0/1 is_cooling = 0/1

status_state_topic: 'insteon/{{address}}/status_state'
status_state_payload: ''{{status}}''

Caution, there is no push update for the hold or energy state. ie, if you press hold on the physical device, you will not get any notice of this unless you run get_status(). There is also no way to programatically change the hold state or energy state

hold_str = 'OFF', 'TEMP' is_hold = 0/1

hold_state_topic: 'insteon/{{address}}/hold_state'
hold_state_payload: '{{hold_str}}'

energy_str = 'OFF', 'ON' is_energy = 0/1

energy_state_topic: 'insteon/{{address}}/energ_state'
energy_state_payload: '{{energy_str}}'

Command Topics

Available variables for templating all of these commands are: address = 'aa.bb.cc' name = 'device name' value = the input payload json = the input payload converted to json. Use json.VAR to extract a variable from a json payload.

Mode state command. The output of passing the payload through the template must match the following:

{ "cmd" : "auto"/"off"/"heat"/"cool","program" }

Sample configuration:

mode_command_topic: 'insteon/{{address}}/mode_command'
mode_command_payload: '{ "cmd" : "{{value.lower()}}" }'

Fan state command. The output of passing the payload through the template must match the following:

{ "cmd" : "auto"/"on" }

Sample configuration:

fan_command_topic: 'insteon/{{address}}/fan_command'
fan_command_payload: '{ "cmd" : "{{value.lower()}}" }'

Temp setpoint commands. The payloads should be in the form of

{temp_c: float, temp_f: float}

Only one unit needs to be present. If temp_f is present it will be used regardless

Sample Configuration:

heat_sp_command_topic: 'insteon/{{address}}/heat_sp_command'
heat_sp_payload: '{ "temp_f" : {{value}} }'
cool_sp_command_topic: 'insteon/{{address}}/cool_sp_command'
cool_sp_payload: '{ "temp_f" : {{value}} }'

Polling

If the 'pair' command has been run correctly, the thermostat should push ambient temp, setpoint temps, humdity, and status message automatically. However if you want, you can poll the device for the status of these values as well by running 'get_status'. This command will also get the units (C or F) specified on the device, which is necessary for properly decoding some of the temp messages from the device. This command is also run as part of a 'refresh'. So if you are seeing strange temperatures, try running this command or 'refresh'

Topic:

insteon/command/aa.bb.cc

Payload:

{ "cmd" : "get_status"}

IOLinc

The IOLinc is both a switch (momentary or latching on/off) and a sensor that can be on or off. There is a state topic which returns the state of both objects, as well as individual relay and sensor topics that only return the state of those objects.

The set-flags command line command can be used to change the mode settings.

There is also a set topic similar to other devices. This obviously can only be used to set the state of the relay. However it may not work as you expect:

  • In Latching mode, the set function works like any other switch. Turning the relay on and off accordingly.
  • If you configure the IOLinc to be momentary, then the ON command will trigger the relay to turn on for the duration that is configured then off. An OFF the command will only cause the relay to turn off, it it is still on because the momentary duration has not fully elapsed yet.
  • The on/off payload forces the relay to on or off IGNORING any special requirements associated with the Momentary_A,B,C functions or the relay_linked flag.

If you want a command that respects the Momentary_A,B,C requirements, you want to create a modem scene and to issue the commands to that scene. See [Scene triggering](#scene triggering) for a description for how to issue commands to a scene. And see Scene Management for a description of how to make a scene and the scenes.yaml file for examples of an IOLinc scene.

In Home Assistant use MQTT switch with a configuration like: switch: - platform: mqtt state_topic: 'insteon/aa.bb.cc/relay' command_topic: 'insteon/aa.bb.cc/set' binary_sensor: - platform: mqtt state_topic: 'insteon/aa.bb.cc/sensor'

Alternatively, to use a modem scene to control the IOLinc switch: - platform: mqtt state_topic: 'insteon/aa.bb.cc/relay' command_topic: "insteon/command/modem" payload_off: '{ "cmd": "scene", "name" : "<>", "is_on" : 0}' payload_on: '{ "cmd": "scene", "name" : "<>", "is_on" : 1}'

State Topic:

'insteon/{{address}}/state'

State Topic Payload:

'{ "sensor" : "{{sensor_on_str.lower()}}"", relay" : {{relay_on_str.lower()}} }'

Relay State Topic:

'insteon/{{address}}/relay'

Payload:

'{{relay_on_str.lower()}}'

Sensor State Topic:

'insteon/{{address}}/sensor'

Payload:

'{{sensor_on_str.lower()}}'

Set Command Topic:

'insteon/{{address}}/set'

Payload: