Updating the maxima separation value #1

Open
neurolabusc opened this issue Sep 20, 2021 · 0 comments
Open

Updating the maxima separation value #1

neurolabusc opened this issue Sep 20, 2021 · 0 comments

Comments

@neurolabusc
Copy link

I realize the author of this useful tool has left for industry. However, as a note for users, if you adjust the maxima separation value, you will need to re-upload the the overlay map in bspmview in order for the new distance parameters to take effect. If you change the value but fail to re-upload the image, the generated tables will claim to use the new separation, but in fact present the data unchanged from when it was loaded.