You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I am trying to upload firmware for Longan Nano v1.1 using RV-Debugger Plus. I connected TCK, TDI, TDO, TMS, 3V3, GND, T0, and R0 lines between them and the debugger is connected to my computer via a USB C-to-A cable. The project configuration is as follows:
; PlatformIO Project Configuration File
;
; Build options: build flags, source filter, extra scripting
; Upload options: custom port, speed and extra flags
; Library options: dependencies, extra library storages
;
; Please visit documentation for the other options and examples
; https://docs.platformio.org/page/projectconf.html
[env:sipeed-longan-nano]
platform = gd32v
framework = gd32vf103-sdk
board = sipeed-longan-nano
monitor_speed = 115200
upload_protocol = sipeed-rv-debugger
Since the default OpenOCD configuration for RV-Debugger finds a device named Dual RS232 and the actual USB device name is JTAG Debugger, I modified sipeed-rv-debugger.cfg in .platformio/packages/tool-openocd-gd32v/share/openocd/scripts/interface/ftdi as follows:
I am trying to upload firmware for Longan Nano v1.1 using RV-Debugger Plus. I connected TCK, TDI, TDO, TMS, 3V3, GND, T0, and R0 lines between them and the debugger is connected to my computer via a USB C-to-A cable. The project configuration is as follows:
Since the default OpenOCD configuration for RV-Debugger finds a device named
Dual RS232
and the actual USB device name isJTAG Debugger
, I modifiedsipeed-rv-debugger.cfg
in.platformio/packages/tool-openocd-gd32v/share/openocd/scripts/interface/ftdi
as follows:With these setups, uploading longan-nano-blink example prints the following output and gets stuck:
Environment
The text was updated successfully, but these errors were encountered: