Notifications
You must be signed in to change notification settings - Fork 1
/
home_manager.py
132 lines (115 loc) · 5.04 KB
/
home_manager.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
import csv
import signal
import datetime
import sys
import time
from openzwave.command import ZWaveNodeSensor
from openzwave.network import ZWaveNetwork
from openzwave.option import ZWaveOption
from pydispatch import dispatcher
def ozw_debug(logger, network):
logger.info("------------------------------------------------------------")
logger.info("Use openzwave library : {}".format(network.controller.ozw_library_version))
logger.info("Use python library : {}".format(network.controller.python_library_version))
logger.info("Use ZWave library : {}".format(network.controller.library_description))
logger.info("Network home id : {}".format(network.home_id_str))
logger.info("Controller node id : {}".format(network.controller.node.node_id))
logger.info("Controller node version : {}".format(network.controller.node.version))
logger.info("Nodes in network : {}".format(network.nodes_count))
logger.info("------------------------------------------------------------")
def value_refresh_to_influxdb_json(node, val):
return {
"measurement": "value_refresh",
"tags": {
'id_on_network': val.id_on_network,
'home_id': node.home_id,
'node_id': node.node_id,
'value_id': val.value_id,
'manufacturer_id': node.manufacturer_id,
'product_id': node.product_id,
'label': str(val.label),
'genre': str(val.genre),
},
"time": time.asctime(time.localtime()),
"fields": {
'label': str(val.label),
'data': str(val.data_as_string),
'units': str(val.units),
'max': str(val.max),
'min': str(val.min),
}
}
def value_refresh_to_csv(node, val):
return [
datetime.datetime.now(),
val.id_on_network, # A sort of sensor UUID
node.home_id, # The home id, a hexadecimal string
node.node_id, # The node id, a number from 1 to n where n is the number of nodes on the network
val.value_id, # The value id, a string that identifies the
node.manufacturer_id, # Manufacturer identifier, useful for knowing which sensor the value is from
node.product_id, # Product identifier, useful for knowing which sensor the value is from
val.data_as_string, # Data read, converted to a string
val.units, # Units of the data, can be empty
val.label, # What kind of data it is
val.min, # Minimum possible value
val.max, # Maximum possible value
]
class HomeManager(object):
def __init__(self, device_path, ozw_log_level, logger):
self.logger = logger
options = ZWaveOption(device_path,
config_path="./venv/lib/python3.%d/site-packages/python_openzwave/ozw_config" % sys.version_info[1],
user_path=".", cmd_line="")
options.set_log_file("OZW.log")
options.set_append_log_file(False)
options.set_save_log_level(ozw_log_level)
options.set_console_output(False)
options.set_logging(True)
options.lock()
self.options = options
self.network = ZWaveNetwork(options, log=None, autostart=False)
self.csvfile = open('output.csv', 'a')
self.writer = csv.writer(self.csvfile)
self.stopping = False
def start(self):
self.logger.info("Starting network...")
self.network.start()
def stop_signal(self, signum, frame):
self.stop()
def stop(self):
if self.stopping:
return
else:
self.stopping = True
self.logger.info("Stopping network...")
self.network.stop()
self.csvfile.close()
self.logger.info("Stopped")
def connect_signals(self):
dispatcher.connect(self.signal_network_ready, self.network.SIGNAL_NETWORK_READY)
signal.signal(signal.SIGINT, self.stop_signal)
# Note -- the name of the network parameter must not change!
def signal_network_ready(self, network):
if self.network is not network:
return
else:
del network
ozw_debug(self.logger, self.network)
self.logger.info("Network is ready!")
dispatcher.connect(self.signal_node_update, self.network.SIGNAL_NODE)
dispatcher.connect(self.signal_value_refreshed, self.network.SIGNAL_VALUE)
# Note -- the names of the network/node/value parameters must not change!
def signal_value_refreshed(self, network, node, value):
if self.network is not network:
return
else:
del network
self.logger.info("Received value refresh %s: %s", value.id_on_network, value)
self.writer.writerow(value_refresh_to_csv(node, value))
self.csvfile.flush()
# Note -- the names of the network/node parameters must not change!
def signal_node_update(self, network, node):
return
@staticmethod
def is_sensor(node):
return isinstance(node, ZWaveNodeSensor) and not len(node.get_sensors()) is 0