title | description | addedAt | pageClass |
---|---|---|---|
Lupus 12126 control via MQTT |
Integrate your Lupus 12126 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2020-01-14 19:34:25 UTC |
device-page |
Model | 12126 |
Vendor | Lupus |
Description | 1 channel relay |
Exposes | switch (state), power_on_behavior, linkquality |
Picture |
How to use device type specific configuration
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Controls the behavior when the device is powered on after power loss.
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, on
, toggle
, previous
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.