Notifications
You must be signed in to change notification settings - Fork 4
/
costing.py
270 lines (196 loc) · 10.2 KB
/
costing.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
'''
Costing is NOT part of the optimizer and should be manually researched and set by the user. However, this is used to
introduce the variable acquisition capabilities of the optimizer.
'''
import math
import numpy as np
import os
def eqn_type_k(c1, c2, c3):
'''
Generates a function that computes a purchase cost based on the format of 3 constant K-values:
log(y) = a + b*log(A) + c*log(A)^2
'''
return lambda x: np.power(10, c1 + c2 * np.log10(x) + c3 * (np.log10(x)**2))
# # Equipment and Utility Cost Parameters
# CEPCI
CEPCI_Actual = 567.5 # Annual Index 2017
CEPCI_2001 = 397 # Base Annual Index
cost_factor = CEPCI_Actual / CEPCI_2001
# Annualization Factor parameters
interest_rate = 0.07
# payback period
n_years = 3
# Utility Costs (in $/kWh) from R.Turton 5th Edition Table 8.3
# Converted from $/GJ to $/kWh
util_water_cost = 0.378 / 1e9 * 3600 * 1e3 # [30 C to 40-45 C]
util_refrig_cost = 4.77 / 1e9 * 3600 * 1e3 # [5 C to 15 C]
util_cryo_cost = 8.49 / 1e9 * 3600 * 1e3 # [5 C to 15 C]
util_steam_cost = 4.54 / 1e9 * 3600 * 1e3 # Low Pressure Steam [5 barg, 160 C]
util_hpsteam_cost = 5.66 / 1e9 * 3600 * 1e3 # High Pressure Steam [41 barg, 254 C]
h_year = 8000 # Operating hours per year
# Equip Cost Equations based on (K). See Appendix A - R .Turton
purchase_cost_tray = eqn_type_k(2.9949, 0.4465, 0.3961) # Area m2
purchase_cost_tower = eqn_type_k(3.4974, 0.4485, 0.1074) # Volume m3
purchase_cost_hx = eqn_type_k(4.3247, -0.3030, 0.1634) # Area m2 - Fixed tube heat exchanger
purchase_cost_kettle = eqn_type_k(4.4646, -0.5277, 0.3955) # Kettle Reboiler
tray_factor = eqn_type_k(0.4771, 0.0816, -0.3473)
# Bare module Cost Factor: direct and indirect costs for each unit
fbm_tray = 1 # Table A.6 & Figure A.9 (Trays - sieve trays)
fbm_tower = (2.25 + 1.82 * 1.0) # Table A.4 & Figure A.8 (Process vessels - vertical (including towers))
fbm_hx = (1.63 + 1.66 * 1.3) # Table A.4 & Figure A.8 (fixed tube sheet)
fbm_kettle = (1.63 + 1.66 * 1.7) # Table A.4 & Figure A.8 (fixed tube sheet)
# Heat exchanger hyperparameters
DTMIN = 10
# Cooler using cooling water or refrigeration
U_cooler = 800 # [W/(m2 K)]
t_water_in = 30 # Cooling water inlet [ºC]
t_water_out = 40 # Cooling water outlet Condenser [ºC]
t_refrig_in = 5
t_refrig_out = 15
t_cryo_in = -20
t_cryo_out = -19
# Heater using steam or HP steam
U_heater = 820 # [W/(m2 K)]
t_steam = 160 # Low Pressure Steam Temperature (R.Turton 4º Ed. Table 8.3)
t_hp_steam = 254 # High Pressure Steam Temperature
# Tower Column
tray_spacing = 0.6096 # [m]
def column_cost_function(column):
'''
Takes in a HYSYS column operation and calculates the total annualized cost (capital + operating cost).
Args:
col: Column operation object
Returns:
Total annualized cost of the column
'''
# Hyperparameters
tray_effic = 0.7
# --- 2 - Import Data from Aspen Hysys Model
n_trays = np.ceil(column.get_num_trays() / tray_effic) # Trays efficiency correction
t_cond_in, t_cond_out = column.get_condenser_temps()
t_reb_in, t_reb_out = column.get_reboiler_temps()
q_cond = column.get_condenser_duty()
q_reb = column.get_reboiler_duty()
# 03 # Run Aspen Hysys Script "Col_diam_V8.SCP" to update column diameter
# Problem.HyObject.HyCase.Application.PlayScript(os.path.abspath('Column_Diameter.SCP'))
column_diameter = column.get_column_diameter() # [m]
# 05 # Capital Cost ##########################################################
# Column dimensions
column_area = np.pi * column_diameter**2 / 4 # Sieve area [m2]
column_height = (n_trays) * tray_spacing + 3 # Tower Height [m]
column_volume = column_area * column_height # Volume Tower [m3]
# Bare Module cost
column_CBM = purchase_cost_tower(column_volume) * fbm_tower * cost_factor
# Column trays
tray_CBM = tray_cost_bm(column_area, n_trays)
# Column Condenser CBM
if t_cond_out >= t_water_in + DTMIN and t_cond_in >= t_water_out + DTMIN:
# Cooling water
lmtd_cond = lmtd(t_cond_in, t_cond_out, t_water_in, t_water_out)
cond_cooling_cost = q_cond * util_water_cost * h_year
elif t_cond_out >= t_refrig_in + DTMIN and t_cond_in >= t_refrig_out + DTMIN:
# Refrigeration
lmtd_cond = lmtd(t_cond_in, t_cond_out, t_refrig_in, t_refrig_out)
cond_cooling_cost = q_cond * util_refrig_cost * h_year
elif t_cond_out >= t_cryo_in + DTMIN and t_cond_in >= t_cryo_out + DTMIN:
# Colder Refrigeration
lmtd_cond = lmtd(t_cond_in, t_cond_out, t_cryo_in, t_cryo_out)
cond_cooling_cost = q_cond * util_cryo_cost * h_year
else:
err_str = "None of the utilities provided can cool stream from {} degC to {} degC.".format(t_cond_in, t_cond_out)
raise ValueError(err_str)
condenser_CBM = heat_exchanger_cost_bm(q_cond, lmtd_cond, U_cooler)
# Column Reboiler CBM (assume Thermosiphon reboiler)
# For a heater, we can use LP steam (160C) or HP Steam (254C)
if t_reb_out <= 160 - DTMIN:
lmtd_reb = lmtd(t_reb_in, t_reb_out, t_steam, t_steam)
reb_heating_cost = q_reb * util_steam_cost * h_year
elif t_reb_out <= 254 - DTMIN:
lmtd_reb = lmtd(t_reb_in, t_reb_out, t_hp_steam, t_hp_steam)
reb_heating_cost = q_reb * util_hpsteam_cost * h_year
else:
err_str = "None of the utilities provided can heat stream from {} degC to {} degC.".format(t_reb_in, t_reb_out)
raise ValueError(err_str)
reboiler_CBM = heat_exchanger_cost_bm(q_reb, lmtd_reb, U_heater)
# 06 # Total Annual Cost #####################################################
# Total Operating Cost
op_cost = cond_cooling_cost + reb_heating_cost
# Total Capital Cost
cap_cost = column_CBM + tray_CBM + condenser_CBM + reboiler_CBM
print("Operating cost breakdown: Condenser={}, Reboiler={}".format(cond_cooling_cost, reb_heating_cost))
print("Capital cost breakdown: Column={}, Trays={}, Condenser={}, Reboiler={}".format(column_CBM, tray_CBM, condenser_CBM, reboiler_CBM))
# # Discounted annualisation factor based on interest rate and payback period
discount = discount_factor(n_years, interest_rate)
total_annualized_cost = (op_cost + cap_cost * discount) * 1e-6 # [MM $/yr]
return total_annualized_cost
def discount_factor(n, i):
return i * (1 + i) ** n / ((1 + i) ** n - 1)
def tray_cost_bm(column_area, n_trays):
# Tray factor
if n_trays < 20:
Fq = tray_factor(n_trays)
else:
Fq = 1
return purchase_cost_tray(column_area) * fbm_tray * Fq * n_trays * cost_factor
def heat_exchanger_cost_bm(q, lmtd, U):
area = q / (U * lmtd) * 1000
return purchase_cost_hx(area) * fbm_hx * cost_factor
def lmtd(t1_in, t1_out, t2_in, t2_out, bypass=True):
# Handles constant temperature by using arithmetic mean instead of log mean
if t1_in == t1_out or t2_in == t2_out:
return np.abs(np.mean([t1_in - t2_out, t1_out - t2_in]))
if bypass:
return ((t1_in - t2_out) - (t1_out - t2_in)) / np.log((t1_in - t2_out) / (t1_out - t2_in))
return ((t1_in - t2_out) - (t1_out - t2_in)) / np.log((t1_in - t2_out) / (t1_out - t2_in))
def pressure_factor(diameter, pressure, ca, t_min, max_stress=944):
# E is weld efficiency
return (pressure * diameter / (2 * max_stress * 0.9 - 1.2 * pressure) + ca) / t_min
def hx_cost_function(hx_op):
'''
Cost functions for heat exchangers. Implemented by interfacing with the COM objects from the optimizer.
Automatically picks a valid utility based on minimum approach temperature of 10degC.
'''
# If no heat load/temp difference is detected, return 0 (no heat exchanger required)
q = abs(hx_op.Duty.GetValue('kW'))
if q == 0:
return 0
# Automatically detect if cooling or heating is required. A heater with negative heat load becomes a cooler, etc
t_in = hx_op.AttachedFeeds.Item(0).Temperature.GetValue('C')
t_out = hx_op.AttachedProducts.Item(0).Temperature.GetValue('C')
if t_in < t_out:
# For a heater, we can use LP steam (160C) or HP Steam (254C)
if t_out <= 160 - DTMIN:
lmtd_heater = lmtd(t_in, t_out, t_steam, t_steam)
cap_cost = heat_exchanger_cost_bm(q, lmtd_heater, U_heater)
op_cost = q * util_steam_cost * h_year
elif t_out <= 254 - DTMIN:
lmtd_heater = lmtd(t_in, t_out, t_hp_steam, t_hp_steam)
cap_cost = heat_exchanger_cost_bm(q, lmtd_heater, U_heater)
op_cost = q * util_hpsteam_cost * h_year
else:
err_str = "None of the utilities provided can heat stream from {} degC to {} degC.".format(t_in, t_out)
raise ValueError(err_str)
else:
# Cooler can either use cooling water (30C-40C) or refrigeration (5C-15C)
if t_out >= t_water_in + DTMIN and t_in >= t_water_out + DTMIN:
# Cooling water
lmtd_cooler = lmtd(t_in, t_out, t_water_in, t_water_out)
cap_cost = heat_exchanger_cost_bm(q, lmtd_cooler, U_cooler)
op_cost = q * util_water_cost * h_year
elif t_out >= t_refrig_in + DTMIN and t_in >= t_refrig_out + DTMIN:
# Refrigeration
lmtd_cooler = lmtd(t_in, t_out, t_refrig_in, t_refrig_out)
cap_cost = heat_exchanger_cost_bm(q, lmtd_cooler, U_cooler)
op_cost = q * util_refrig_cost * h_year
elif t_out >= t_cryo_in + DTMIN and t_in >= t_cryo_out + DTMIN:
# Cryogenic Refrigeration
lmtd_cooler = lmtd(t_in, t_out, t_cryo_in, t_cryo_out)
cap_cost = heat_exchanger_cost_bm(q, lmtd_cooler, U_cooler)
op_cost = q * util_cryo_cost * h_year
else:
err_str = "None of the utilities provided can cool stream from {} degC to {} degC.".format(t_in, t_out)
raise ValueError(err_str)
# Discounted annualisation factor based on interest rate and payback period
discount = discount_factor(n_years, interest_rate)
total_annualized_cost = (op_cost + cap_cost * discount) * 1e-6
return total_annualized_cost