You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When using option --multiple and option --mrange, we get a Segmentation Fault error in a child process when doing a test using both web-socket based client (ndt-sonar) and the web100clt utility.
The only way to make concurrent tests work is by not having a pre-defined set of TCP port range and let the system decide randomly of TCP port per connection.
[2017-02-09T11:28:08.168722Z pid=20931 loglevel=1 web100srv.c:2454] ANL/Internet2 NDT ver 4.0.0.1
[2017-02-09T11:28:08.168792Z pid=20931 loglevel=1 web100srv.c:2455] Variables file = /usr/local/ndt/web100_variables
[2017-02-09T11:28:08.168812Z pid=20931 loglevel=1 web100srv.c:2456] log file = /var/log/web100srv.log
[2017-02-09T11:28:08.168817Z pid=20931 loglevel=1 web100srv.c:2464] Debug level set to 5
[2017-02-09T11:28:08.168849Z pid=20931 loglevel=3 web100srv.c:2466] Extended tests options:
[2017-02-09T11:28:08.168856Z pid=20931 loglevel=3 web100srv.c:2469] * upload: duration = 10000, streams = 1, throughput snapshots: enabled = false, delay = 5000, offset = 1000
[2017-02-09T11:28:08.168862Z pid=20931 loglevel=3 web100srv.c:2472] * download: duration = 10000, streams = 1, throughput snapshots: enabled = false, delay = 5000, offset = 1000
[2017-02-09T11:28:08.168981Z pid=20931 loglevel=5 network.c:196 ] Send buffer initialized to 87380,
[2017-02-09T11:28:08.168994Z pid=20931 loglevel=5 network.c:200 ] Receive buffer initialized to 87380
[2017-02-09T11:28:08.169003Z pid=20931 loglevel=1 web100srv.c:2518] server ready on port 3001 (family 0)
[2017-02-09T11:28:08.169121Z pid=20931 loglevel=1 web100-util.c:135 ] web100_init() read 69 variables from file
[2017-02-09T11:28:12.424620Z pid=20931 loglevel=5 web100srv.c:1715] Parent process spawned child = 20932
[2017-02-09T11:28:12.424665Z pid=20931 loglevel=5 web100srv.c:1717] Parent thinks pipe() returned fd0=6, fd1=7
[2017-02-09T11:28:12.424817Z pid=20931 loglevel=5 web100srv.c:1715] Parent process spawned child = 20933
[2017-02-09T11:28:12.424843Z pid=20931 loglevel=5 web100srv.c:1717] Parent thinks pipe() returned fd0=6, fd1=8
[2017-02-09T11:28:12.427528Z pid=20932 loglevel=4 web100srv.c:1690] New connection received from 0x1c24090 [maxime.e-tera.com] sockfd=8.
[2017-02-09T11:28:12.427633Z pid=20932 loglevel=5 logging.c:561 ] Protocol logging is not enabled
[2017-02-09T11:28:12.427640Z pid=20932 loglevel=4 web100srv.c:1705] Child thinks pipe() returned fd0=6, fd1=7 for pid=0
[2017-02-09T11:28:12.430472Z pid=20932 loglevel=1 testoptions.c:340 ] Client version: 3.5.5-
[2017-02-09T11:28:12.430495Z pid=20932 loglevel=1 testoptions.c:355 ] Client connect received from :IP 192.168.4.223 to some server on socket 8
[2017-02-09T11:28:12.431275Z pid=20932 loglevel=5 logging.c:718 ] Protocol logging is not enabled
[2017-02-09T11:28:12.433855Z pid=20932 loglevel=3 web100srv.c:1536] Valid test sequence requested, run test for client=20932
[2017-02-09T11:28:12.433889Z pid=20932 loglevel=4 web100srv.c:738 ] Child process 20932 started
[2017-02-09T11:28:12.434864Z pid=20932 loglevel=5 logging.c:718 ] Protocol logging is not enabled
[2017-02-09T11:28:12.434884Z pid=20932 loglevel=3 web100srv.c:758 ] run_test() routine, asking for test_suite = 2 4 32
[2017-02-09T11:28:12.434893Z pid=20932 loglevel=5 logging.c:718 ] Protocol logging is not enabled
[2017-02-09T11:28:12.434897Z pid=20932 loglevel=1 web100srv.c:762 ] Starting test suite:
[2017-02-09T11:28:12.434902Z pid=20932 loglevel=1 web100srv.c:770 ] > C2S throughput test
[2017-02-09T11:28:12.434907Z pid=20932 loglevel=1 web100srv.c:776 ] > S2C throughput test
[2017-02-09T11:28:12.434911Z pid=20932 loglevel=1 web100srv.c:782 ] > META test
[2017-02-09T11:28:12.434946Z pid=20932 loglevel=1 test_c2s_srv.c:313 ] <-- 20932 - C2S throughput test -->
[2017-02-09T11:28:12.434980Z pid=20932 loglevel=5 logging.c:508 ] Protocol logging is not enabled
[1486636092 SIGNAL_HANDLER pid=20932 loglevel=1 signal=11 (Segmentation fault)] Received a signal
[1486636092 SIGNAL_HANDLER pid=20931 loglevel=1 signal=17 (Child exited)] Received a signal
[1486636092 SIGNAL_HANDLER pid=20931 loglevel=5 signal=17 (Child exited)] Signal 17 (SIGCHLD) received - completed tests
The text was updated successfully, but these errors were encountered:
I am using the web100srv binary with the support of multiple concurrent tests and a set of defined TCP ports of the NDTP test.
When using option --multiple and option --mrange, we get a Segmentation Fault error in a child process when doing a test using both web-socket based client (ndt-sonar) and the web100clt utility.
The only way to make concurrent tests work is by not having a pre-defined set of TCP port range and let the system decide randomly of TCP port per connection.
The text was updated successfully, but these errors were encountered: