from pymodbus.constants import Endian
from pymodbus.client import ModbusTcpClient
from pymodbus.payload import BinaryPayloadBuilder
import time
import random
# Connect to OpenPLC
client = ModbusTcpClient('localhost', port=502) # Adjust the IP and port as needed
# Constants
TANK_VOLUME_ML = 900 # (32floz ~ 946mL) # ~72s to fill @ 45000/3600=12.5mL/sec rate (not incl. dosing)
DOSE_VOLUME_ML = 5 # Adjust the dose volume as needed
# Mapping based on https://autonomylogic.com/docs/2-5-modbus-addressing/
# may change based on hardware target
# Actuator mapping
ACT = {
"red_doser": 6, # QX0.6
"blue_doser": 7, # QX0.7
"pump": 4, # QX0.4
}
# Sensor mapping
SENS = {
"water_level": -1,
"red_RGB": 0, # IW0 Program assumes RGB are sequential
"green_RGB": 1, # IW1
"blue_RGB": 2, # IW2
"range_sensor": 3 # IW3
}
# Initial state
water_volume_ml = 0
range_sensor = 100 # 100% range = empty container, min is 94% full (range sense = 6)
red_ml = 0
blue_ml = 0
red_concentration = 0
blue_concentration = 0
fill_rate_mlph = 45000 # Assuming an average fill rate of 45 Liters per Hour
step = 0
try:
while True:
# Simulate the filling of the tank
step += 1
range_sensor = 100*(1 - water_volume_ml/TANK_VOLUME_ML)
pump_result = client.read_coils(ACT['pump'])
print(f"{pump_result=}", f"{pump_result.bits=}")
if not pump_result.isError() and pump_result.bits[0]: # pump is on TODO: read pump var
water_volume_ml += fill_rate_mlph / 3600 # Increment the water volume (convert GPH to GPM)
# Read the state of the dosers from OpenPLC
#response = client.read_holding_registers(4, 2) # Assuming addresses 4 and 5 for the red and blue dosers
#response = client.read_holding_registers(ACT["red_doser"], 2) # also gets blue doser in this case
response = client.read_coils(ACT["red_doser"], 2) # also gets blue doser in this case
print(response.bits)
if not response.isError():
red_dose, blue_dose = response.bits[0], response.bits[1]
## not sure if this dosing logic is correct
#if red_dose: # # Simulate the dosing of red color # red_concentration += DOSE_VOLUME_ML / water_volume_ml
#if blue_dose:
# # Simulate the dosing of blue color
# blue_concentration += DOSE_VOLUME_ML / water_volume_ml
if red_dose:
# Simulate the dosing of red color
red_ml += DOSE_VOLUME_ML
water_volume_ml += DOSE_VOLUME_ML # accounting for dose volume
if blue_dose:
# Simulate the dosing of blue color
blue_ml += DOSE_VOLUME_ML
water_volume_ml += DOSE_VOLUME_ML # accounting for dose volume
if water_volume_ml > TANK_VOLUME_ML:
# assuming uniform mixing (semi-realistic overflow concentration losses)
overflow = water_volume_ml - TANK_VOLUME_ML
red_ml -= .5 * overflow * red_concentration
blue_ml -= .5 * overflow * blue_concentration
water_volume_ml = TANK_VOLUME_ML # Cap the water volume at the tank capacity
if water_volume_ml > 0:
red_concentration = red_ml / water_volume_ml
blue_concentration = blue_ml / water_volume_ml
# Write the simulated sensor readings to OpenPLC
client.write_registers(SENS["red_RGB"], [int(red_concentration*255), 0, int(blue_concentration*255)])
client.write_registers(SENS["range_sensor"],int(range_sensor*100))
#builder = BinaryPayloadBuilder(byteorder=Endian.BIG, wordorder=Endian.BIG)
#builder.add_32bit_float(range_sensor)
#payload = builder.build()
#payload = client.convert_to_registers(range_sensor, float)
#print(payload)
#client.write_register(SENS["range_sensor"], range_sensor)
#client.write_registers(SENS["range_sensor"], payload, skip_encode=True)
#@client.write_register(0, int(water_volume_ml)) # Assuming address 0 for the water volume sensor
#@client.write_registers(1, [int(red_concentration * 255), 0, int(blue_concentration * 255)]) # Assuming addresses 1, 2, and 3 for the RGB sensor
print(f'Water Vol: {water_volume_ml:.2f} ml (range={range_sensor:.2f}), Red Conc: {red_concentration:.2f}, Blue Conc: {blue_concentration:.2f}, ([{int(red_dose)},{int(blue_dose)}],t={step},r={red_ml:.2f},b={blue_ml:.2f})')
else:
print(f'Error reading from OpenPLC: {response}')
time.sleep(1) # Adjust the sleep time as needed
except KeyboardInterrupt:
pass # Exit the loop on Ctrl-C
client.close()