I'm using Growatt Thos 11 A/S charger with firmware THOR_11AS-V5.2.4-20230307-NOVO. HASS Version: 2024.12.5,
OCPP version: 0.7.0
Describe the bug
Session energy and Active Import Register sensors are always 0. The charger returns correct data in Energy.Active.Import.Register, StopTransaction and in DataTransfer messages. See the log below
To Reproduce
Steps to reproduce the behavior:
Start charging session. Watch sensors do not update
Stop charging session. Watch sensors = 0
Expected behavior
Session Energy and Active Import Register sensors display correct value
Additional context
Looking at the log and code in chargepoing.process_measurands(),
{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh" entry
probably overrides the previous entry
{"value":"4369","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},
Question is:
Should the context other than Sample.Periodic be ignored in this function?
Or should the Charger be configured as OCPP 2.0.1 ?
Logs
`
7607,"meterValue":[{"timestamp":"2025-01-03T19:01:48+01:00","sampledValue":[{"value":"4369","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"2.4","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"236.1","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L1","unit":"V"},{"value":"236.5","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L2","unit":"V"},{"value":"237.3","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L3","unit":"V"},{"value":"386","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"33.0","context":"Sample.Periodic","format":"Raw","measurand":"Temperature","unit":"Celsius"}]}]}]
2025-01-03 19:01:48.393 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2304",{}]
2025-01-03 19:01:53.822 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2305","StatusNotification",{"connectorId":1,"errorCode":"EVCommunicationError","info":"ChargeWait","status":"SuspendedEV"}]
2025-01-03 19:01:53.839 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2305",{}]
2025-01-03 19:04:53.812 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2309","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"","status":"Finishing"}]
2025-01-03 19:04:53.830 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2309",{}]
2025-01-03 19:04:56.894 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2310","StopTransaction",{"idTag":"96DA565A","meterStop":4369,"timestamp":"2025-01-03T19:04:56+01:00","transactionId":1735917607,"reason":"Other","transactionData":[{"timestamp":"2025-01-03T19:04:56+01:00","sampledValue":[{"value":"4369","context":"Transaction.End","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}]
2025-01-03 19:04:56.935 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2310",{"idTagInfo":{"status":"Accepted"}}]
2025-01-03 19:04:57.179 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2311","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"","status":"Preparing"}]
2025-01-03 19:04:57.195 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2311",{}]
2025-01-03 19:04:57.398 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2312","DataTransfer",{"vendorId":"Growatt","messageId":"currentrecord","data":"id=27&connectorId=1&chargemode=1&plugtime=2025-01-03 16:19:44&unplugtime=2025-01-03 19:04:56&starttime=2025-01-03 16:20:07&endtime=2025-01-03 19:04:56&costenergy=4369&costmoney=48&transactionId=1735917607&workmode=7"}]
2025-01-03 19:04:57.426 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2312",{"status":"Accepted"}]
`
The text was updated successfully, but these errors were encountered:
altserg
changed the title
Growatt Thor 11A/S: Session energy always 0
Growatt Thor 11A/S: Session Energy and Active Import Register sensors are always 0
Jan 4, 2025
Proposed solution for Option 1. Add following code around lines ~775 in chargeppoint.py process_measurands() function and import ReadingContext from ocpp library
774 # Only set the meter start value from Transaction begin context
775 if (
776 is_transaction
777 and context == ReadingContext.transaction_begin.value
778 ):
779 self._metrics[csess.meter_start].value = value
780 self._metrics[csess.meter_start].unit == unit
781 continue
782 # End
altserg
added a commit
to altserg/ocpp
that referenced
this issue
Jan 9, 2025
I'm using Growatt Thos 11 A/S charger with firmware THOR_11AS-V5.2.4-20230307-NOVO. HASS Version: 2024.12.5,
OCPP version: 0.7.0
Describe the bug
Session energy and Active Import Register sensors are always 0. The charger returns correct data in Energy.Active.Import.Register, StopTransaction and in DataTransfer messages. See the log below
To Reproduce
Steps to reproduce the behavior:
Expected behavior
Session Energy and Active Import Register sensors display correct value
Additional context
Looking at the log and code in chargepoing.process_measurands(),
{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh" entry
probably overrides the previous entry
{"value":"4369","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},
Question is:
Logs
`
7607,"meterValue":[{"timestamp":"2025-01-03T19:01:48+01:00","sampledValue":[{"value":"4369","context":"Sample.Periodic","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"0","context":"Transaction.Begin","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"},{"value":"2.4","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L1","unit":"A"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L2","unit":"A"},{"value":"0.0","context":"Sample.Periodic","format":"Raw","measurand":"Current.Import","phase":"L3","unit":"A"},{"value":"236.1","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L1","unit":"V"},{"value":"236.5","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L2","unit":"V"},{"value":"237.3","context":"Sample.Periodic","format":"Raw","measurand":"Voltage","phase":"L3","unit":"V"},{"value":"386","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L1","unit":"W"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L2","unit":"W"},{"value":"0","context":"Sample.Periodic","format":"Raw","measurand":"Power.Active.Import","phase":"L3","unit":"W"},{"value":"33.0","context":"Sample.Periodic","format":"Raw","measurand":"Temperature","unit":"Celsius"}]}]}]
2025-01-03 19:01:48.393 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2304",{}]
2025-01-03 19:01:53.822 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2305","StatusNotification",{"connectorId":1,"errorCode":"EVCommunicationError","info":"ChargeWait","status":"SuspendedEV"}]
2025-01-03 19:01:53.839 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2305",{}]
2025-01-03 19:04:53.812 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2309","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"","status":"Finishing"}]
2025-01-03 19:04:53.830 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2309",{}]
2025-01-03 19:04:56.894 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2310","StopTransaction",{"idTag":"96DA565A","meterStop":4369,"timestamp":"2025-01-03T19:04:56+01:00","transactionId":1735917607,"reason":"Other","transactionData":[{"timestamp":"2025-01-03T19:04:56+01:00","sampledValue":[{"value":"4369","context":"Transaction.End","format":"Raw","measurand":"Energy.Active.Import.Register","unit":"Wh"}]}]}]
2025-01-03 19:04:56.935 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2310",{"idTagInfo":{"status":"Accepted"}}]
2025-01-03 19:04:57.179 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2311","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"","status":"Preparing"}]
2025-01-03 19:04:57.195 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2311",{}]
2025-01-03 19:04:57.398 INFO (MainThread) [ocpp] CHM00003232208F3: receive message [2,"2312","DataTransfer",{"vendorId":"Growatt","messageId":"currentrecord","data":"id=27&connectorId=1&chargemode=1&plugtime=2025-01-03 16:19:44&unplugtime=2025-01-03 19:04:56&starttime=2025-01-03 16:20:07&endtime=2025-01-03 19:04:56&costenergy=4369&costmoney=48&transactionId=1735917607&workmode=7"}]
2025-01-03 19:04:57.426 INFO (MainThread) [ocpp] CHM00003232208F3: send [3,"2312",{"status":"Accepted"}]
`
The text was updated successfully, but these errors were encountered: