You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Took a bit of effort but work wonderfully now. Thank you for sharing your efforts.
Motherboard: HP Angelica2
Controller: HP P410
Enclosure: HP D2700 (x2)
OS: Ubuntu Server 20.04 as well as TrueNAS SCALE both working
Other Details:
Smart Array P410 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PACCRCN80ZG1TQA
Cache Serial Number: PBCDF0CRH0C1Y5
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 6.64
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: Not Configured
Drive Write Cache: Disabled
Total Cache Size: 1024 MB
Total Cache Memory Available: 912 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Took a bit of effort but work wonderfully now. Thank you for sharing your efforts.
Motherboard: HP Angelica2
Controller: HP P410
Enclosure: HP D2700 (x2)
OS: Ubuntu Server 20.04 as well as TrueNAS SCALE both working
Other Details:
Smart Array P410 in Slot 1
Bus Interface: PCI
Slot: 1
Serial Number: PACCRCN80ZG1TQA
Cache Serial Number: PBCDF0CRH0C1Y5
RAID 6 (ADG) Status: Disabled
Controller Status: OK
Hardware Revision: C
Firmware Version: 6.64
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 0 secs
Cache Board Present: True
Cache Status: Not Configured
Drive Write Cache: Disabled
Total Cache Size: 1024 MB
Total Cache Memory Available: 912 MB
No-Battery Write Cache: Disabled
Cache Backup Power Source: Capacitors
Battery/Capacitor Count: 1
Battery/Capacitor Status: OK
SATA NCQ Supported: True
Expander 250
Device Number: 250
Firmware Version: 0144
WWID: 5001438001A68FBF
Port: 2I
Box: 1
Vendor ID: HP
Enclosure SEP (Vendor ID HP, Model D2700 SAS AJ840A) 248
Device Number: 248
Firmware Version: 0144
WWID: 5001438001A68FBE
Port: 2I
Box: 1
Vendor ID: HP
Model: D2700 SAS AJ840A
SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249
Device Number: 249
Firmware Version: RevC
WWID: 50014380092FF5AF
Vendor ID: PMCSIERA
Model: SRC 8x6G
The text was updated successfully, but these errors were encountered: