Notifications
You must be signed in to change notification settings - Fork 3
/
change_log.txt
366 lines (337 loc) · 15.7 KB
/
change_log.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
--------------------------
Done
--------------------------
STARTED Add new commandline option to FLOW=X to enable XON/XOFF mode
2.0.0.71
Default send file renamed from capture.txt to send.txt
2.0.0.70
Port Scanning has been completely changed for WinNT and above.
WinNT+ :Ports are not scanned, they are loaded from registry to comport
combobox in form "4 = \VCP0". Sorted by com number. No longer shows
scanports form.
The "scanports" commandline parameter won't be needed now, as
bluetooth ports don't cause delays
WinME- :Scanned by opening the same as before.
Please report any problems especially on old versions of Windows (pre XP eg Win98)
When a port of style \VCP doesn't exist, it no longer tries it as telnet port
2.0.0.69
Fix to pass quoted strings on command line through to FIRST instance
No longer shows Spy driver donate dialog after driver installation.
Change various send string drop downs to use TerminalHex font to display all 8 bit values
added printerport driver files to dlportio.dll install section
2.0.0.68 - Interim release for Steve Mayall
Mask MSB added
Work begun on hexcsv formatting
2.0.0.67
Make data triggers work in stand-alone mode to make testing easier. (previously only in ActiveX mode)
Improve I2C scan to use ":" to make more reliable scanning smbus devices with timeout
2.0.0.66
Fix error box from registry key reads on some systems
Added HEXCSV commandline param to set the format string
Change timing of scanports form display - seems to have sped up scanning
2.0.0.65
Virtual Comports (USB): Comport can be given using Key instead of the com number.
The key names are in the registry list of comm devices at HKLM\HARDWARE\DEVICEMAP\SERIALCOMM
eg an I2C2PC adaptor will be \VCP0, regardless of which port it is attached to
Display the port registry entries on the scanports dialog...
HEXCSV2DEC commandline utility added to Realterm installer
HexCSV formatted display mode begun, not working yet.
Add Channel to MAX127 I2C ADC control, fix rang&sign bits
Add RSS news link to About box
Add DataTriggerSet routine to setup trigger conditions from COM/ActX interface
Remove obsolete KCDXO tab and code
Splitting I2C support routines into separate unit
add windowsplatform to aboutbox
add INSTALL parameter for installer to use to display help, news etc after installation
2.0.0.64
Add COLOR commandline parameter to set terminal colors
Caption is now also used to set the title displayed on startbar when minimised
lengthen tooltip time, by request 2.5s -> 3.5s
Added I2C Scan Bus function to I2C tab.
Added I2C Control Register support
2.0.0.63
Add a Sync Match Counter to "Binary Sync Chars".
-Also uses data trigger color in (yellow) TrayIcon for a few seconds
add version info to aboutbox
2.0.0.62
Fix double counting of incoming chars. (disables routine associated with asc7511)
Fix SPY mode not displaying char(0)
Added BitBashPins box to I2CMisc tab for open drain bashing of all port pins.
Added new ActiveX props: CaptureAsHex
As activeX lib has changed may need to unregister and re-register
Tried translate again - still errors.
2.0.0.61
Commandline parser changed (but not heavily tested)
- quotes in parameters are now OK
- accepts leading - or / before parameters
SendStr and SendNum can be called repeatedly to push the strings into the
SendString combo-boxes so they can be pre-populated
2.0.0.60
Improve Bicolor led display test routine.
When port is closed by button, Terminal is enabled so scrollback continues to work
Added Checksum8 and Checksum16 to Send CRC options
Help commandline option now runs help
2.0.0.59
Fixed Matlab format TimeStamp values.
2.0.0.58
Added SCROLLBACK commandline parameter
Fixed Scanport operation when port is specified, for quick reliable startup.
- if PORT is set on command line, don't scan for ports, unless scanports also set on command line
2.0.0.57
Add new links to about box: Help forum, ChangeLog, Examples
Added a button to bring up the popup menu to make it easier to find.
2.0.0.56
Seem to have fixed "no receive chars in terminal" problem" when start up port does not exist.
2.0.0.55
Now uses FirstAvailablePort (not com1) to open. This is for laptops without COM1
Consequence is that I now do search com1-4 for 1st port if scanports=0
Hopefully will help with the terminal doesn't work problem.
Temporarily added Enable Terminal button to MISC tab for debugging (didn't help)
2.0.0.54
Restore binary sync with AND and XOR fields
Move HexEmulator code into separate module
Add Leading Sync option, but only works for 1 char sync ....
2.0.0.53
Add Readme and Changelog to Realterm shortcuts
fixed starting minimised in 2.0.0.52
Improve Scanports dialog slightly. Now brings up a message box to confirm abort scanning if too slow.
2.0.0.52
Fix for crash when using FIRST commandline parameter to send to running instance
stop form flashing up when using FIRST commandline parameter to send to running instance
Many more examples (installer script fixed)
2.0.0.51
Try to fix EBAUD/EFLOW not correctly activated after being set from command line
2.0.0.50
Add EFLOW commandline option
Add Test button for M5451 LED display modules
Add color checkbox for M5451 LED display modules
2.0.0.49
Add Send^C and Send Break items to rightclick menu
Fix to cope with SCANPORTS=0 on commandline
**Very ODD** ctrl+C has started working from the keyboard in the terminal. Also BREAK key sends ^C now
May remove the ^C menu item in future if this is generally true.
2.0.0.48
Add PCA9545 control to I2C-2 tab to support new MUX3 pcb
2.0.0.47
Add CRC8 algorithms (smbus & dallas 1 wire) to send tab
Added Telnet/Raw radio buttons for Echo port. (Changed code on main port also)
Working on WaitForDataTrigger
BlueSmirf on misc tab:
- Fix baud rate setting command
- add query baud button
Clear LineError light after 1 sec. Leaves state on hint until double click on "Error" label
BaudRate setting:
-Added hidden BaudMultiplier drop down to help with high baud rates on 950 uarts
-trap error message during (invalid) baud rate setting to give more informative message (tested on WinXP)
Update BL301 controls on I2C-2 tab for current commands
Merge sboyd changes to AWASCII module. Should have no effect on Realterm.
2.0.0.46
Timestamping in capture file working (user feedback needed about perferred YMD format)
Capture-as hex working
statusbar toggles to show longhints
disable Freeze button (until it is fixed)
spinning icon extended to yellow corner for data-triggers
added Events tab, which is hidden except when started as activeX server
2.0.0.45 ***Last version before activeX type library is extended ***
Add Terminal Columns spinedit on display tab
Add warning if try to capture when port is closed
ActiveX Callback events
-OnCaptureCount (called once only when thresh crossed. Only comes from direct Capture)
-OnCaptureStop (both will be called if there is a count threshold)
-OnTimer: This is a dedicated timer for generating periodic callbacks.
- Control on Misc tab to manually send events to help client code testing. Not gated by Enables, so always sent
- update Matlab example to show events
First version compiled on new PC, For proven version use 2.0.0.43
Donate button
add cancel button to form close dialog when in spy mode
Installer changes
-rename dlportio installer to install_dlportio.exe
-Installer for SpyMode drivers available to project donors.
2.0.0.43 **This is a well tested and stable version**
Change Capture to try and fix reported Div0 errors
Add Max127 I2C read
2.0.0.42
commandline option "echo" with no further data crashes (was expecting "echo=<port>"
now will accept nothing OK
Change to combobox history list routine that is widely used. Should have no side-effects.
2.0.0.41
Fixes for multi-copy COM automation:
Creates multiple instances instead of one single instance again (like 1.99.XX)
Automation opens it with ports closed again (like 1.99.XX)
Caption now "Realterm: Automation server" for automation instances
Suppresses port scanning when started as ActiveX/COM server
2.0.0.40
Added LF button to send tab
2.0.0.39
Fixed Font selector to change size and style correctly
2.0.0.38
fix to M5451 conversions so that "-1.23" doesn't light segment in digit 5
2.0.0.37
Added Float4 single-precision floating point display
2.0.0.36
Added Binary and Nibble display modes. One of these will be dropped in future
version, probably "binary"
2.0.0.35
Swapped trace and log control positions to put emphasis on log files.
2.0.0.34
Added some BlueSmirf bluetooth module commands to misc tab
Changed scanports commandline option to specify last port number to scan for.
This makes it easier to limit the time taken when bluetooth is present without
just disabling it
Add ScanPort dialog when it is taking too long.
Change port scanning to scan upward to allow aborting
2.0.0.33
Indirect capture opens files for shared-reading during capture
(ie capture while displaying chars in terminal)
Modified AdTrmEmu.pas for this
F1 key now brings up help.
Update aboutbox
2.0.0.32
cleaned up activeX TLB to remove warnings
Added Version property to activeX
2.0.0.31
Added controls to set Trace and log file names
Added clear and dump buttons for trace/log
Now capture,send correctly append to combobox
tabsheet send correctly selected during send
Only show Binary sync in hex modes where it is active
Added active X method "AddCannedSendString" that pushes strings into the sendstring combo boxes
2.0.0.30
Added DTR&RTS activeX fields
Fixed Read Dallas1 wire ID
Added PCA9544 I2C device
removed translate component due to ntdll errors
Added CAPDIRECT commandline and activeX
hints copied into status panel
2.0.0.27
added scrollback rows field
fixed commandline LFNL
hack to remove "buffer empty" error during capture. Breakss BL301 and ASC7511 reading
Added 1-wire temp read button for DS1820 (untested)
I2C link now sets RTS/CTS
Warning in status panel about no handshaking
panels swapped about
attempt to use long hints in panel (not working yet)
2.0.0.26
Added CTS,DSR,DCD,Break lights to Echoport tab to enhance monitor mode.
Correctly enable status lights on echo port
fixed monitor assert failure in echo monitor mode
2.0.0.24
stretched Pin Description memo to fit properly
2.0.0.23
Added buttons for SPI CS pin control
added and removed mod for comserv startup problem on winxp
spymode bleat screen
2.0.0.21
Added Andigilog aSC7511 I2C support
2.0.0.20
Now scrollbars will appear when realterm is resized so terminal window is smaller than number of lines
made ascii edit into combo-box, and added regular expansion
BL301 I2C support
new I2CADD command line parameter to set I2C address
2.0.0.19
Added I2C buttons to "write then read" to make it easier to read eeproms etc.
Fixed "invert data" and char counting in ASCII emulator
Char count now only counts chars from the port, and ignores chars being sent in Half duplex
EOL char for Sendfile EOL delay is now LF not CR
2.0.0.18
Add humidity sensor support to I2C Misc tab
Added I2CMisc tab for non-i2c chips
Moved Sendfile to Capture tab to free up space on send tab
commandline setting of emulator doesn't work
2.0.0.17
New installer based on NSI. Now installs fonts
Colorise spy mode
proper error messages when opening port
no rx when port already open while opening a second instance
clear terminal when changing port (w/ checkbox)
paste to port/copy from port have some issues
scrollback
grayed unused port options
F1 help launches web browser
fixed bug that meant no display of control chars after switching back. (Emulator_ASCII is unused now)
spy mode check that port is closed before trying to enter spy mode. Or warn
changed spy mode to use teta. Works properly now
fixed: first locks error (still flashes but works.
fixed: capquit error
active scripting examples
enumerating all comports can be disabled, and run (actx control?)
recieving repeated FF or FF's lost on TCP (cmdline and actx?)
CAPTION doesn't work from command line...
fix repeated file send and send messages
sendfile delay control can go negative
sendfile delay locks w/ big numbers
sendfile repeats work properly
exception when exiting via COM or commandline interface
FLOW=3 RS485 mode can be set from command line now
------------------------------------------
Bugs
------------------------------------------
Scrollback command line option does not work. (seem to at 2.0.0
help commandline option errors when port scan is slow.
Binary sync mode
-doesn't seem to update correctly until after mode changed back to ascii then back to hex
-perhaps should be active in ascii, but not ansi
-and masking doesn't seem to work right. Check. Correct or improve explanation
Freeze button no longer working. (works in 1.99.16). Code unchanged. (bug in APRO)
Reported RS485 problems. Not checked, but is a known windows bug due to slow RTS timing (see apro forums)
------------------------------------------
Not really faults
------------------------------------------
showallemulator shows BS as triangle (no: ^H doesn't send BS)
-----------------
ToDo .... maybe
-----------------
Spy mode Capture file
Installer improvements:
-run it if user chooses to install
-or improve installer wording so user knows to install separately
-add all modified components
ability to launch from com interface then detach and leave running.
extend special font with larger sizes
update to latest async port components, and merge my changes back to SF.
RFC2217 remote port control function
modbus packets, ascii? bin?
CRC's
-more generally add a range of checksum/crc's: CK8,CK16,ModbusAscii,ModbusCRC,CRC16,CRC32
translations
command file
general printer port toggle controls
explicit printer port address
Tidy up dlportio -add routines, merge d3 and d4 versions
redundant color setting methods
clean up SendString mess
hex getting for I2C
getstring or getline for activeX interface
autosize for winxp, autosizing screen at start - doesn't seem to be needed now
crc packet sync
translation support
autobaudrate detection scheme
linedelay and chardelay are longer than supposed to be, especially for short delays
Kylix version.
use canned strings. (implemented from Actx, but not commandline)
easy way to add i2c chip addresses. (done - AddCannedStrings)
Add CRLF key eg shift+return
SENDDLY commandline does not set SENDREPS=0 like documentation.
As it has been commented out for reasons forgotten, I am a bit loathe to restore it.
--------------------------
Feature Requests
--------------------------
Spy mode capture file
Resize changes rows/cols
It would very useful to add command line options for font and font size choose on program start.
It would be nice if the sync chars would allow random length "Data Frames" when set to "Single", without the data frame size speifically set. I.E. header byte set to
AND $80 (MSB set) and variable length messages to
follow.
Delay on repeats of the Send comboboxes
Key for Break and for ^C
handle - and -- in commandline arguments ie -scanports=2
fix scanports to abort properly or to run in background, and to display dialog after mainform is visible.
Send multiple files from command line
Delays for other send options and normal terminal
A "sync feature" that will allow closing and re-opening the capture files with an incremented name.
The plot files from the scope are HPGL and have a known ending sequence. So it
would be nice to start the capture, and wait for the stream to come from the
, including its termination set, then close the current capture file, and start
a new one automatically. Later I can go in and print out the capture files directly.
This would make Realterm a standalone, rather than embedding it in a second pgm.