Notifications
You must be signed in to change notification settings - Fork 10
/
Copy pathHumidifierSensor.ino
53 lines (38 loc) · 1.72 KB
/
HumidifierSensor.ino
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
#include <CapacitiveSensor.h>
#define SENDER_PIN 3
#define SENSOR_PIN 2
#define SAMPLES_NUMBER 1000
#define TIMEOUT_MS 500
#define MIN_READING 4200 // for 1M resistor and 1000 samples
#define MAX_READING 11000 // for 1M resistor and 1000 samples
byte packet[] = {0xFA, 0x29, 0x03, 0x00, 0x00, 0x00, 0x00, 0x14, 0x9A, 0x00, 0x00, 0x00, 0x03, 0x77, 0x72, 0x71, 0x03, 0x00, 0x6C, 0x4C, 0x3B, 0x03, 0x2F, 0x15, 0x00, 0x00, 0x00, 0x02, 0x00, 0x00, 0x00, 0x21, 0x00, 0x00, 0x03, 0xE8, 0x00, 0x2c, 0x02, 0x6D, 0x37, 0xD2, 0x00};
byte checksum;
byte mappedValue;
long readingRaw;
CapacitiveSensor sensor = CapacitiveSensor(SENDER_PIN,SENSOR_PIN); // 1M resistor between pins 3 & 2, pin 2 is sensor pin
void setup()
{
sensor.set_CS_AutocaL_Millis(0xFFFFFFFF); // turn off autocalibrate
sensor.set_CS_Timeout_Millis(TIMEOUT_MS);
Serial.begin(9600);
}
void loop()
{
checksum = 0;
packet[11] = 0;
readingRaw = sensor.capacitiveSensorRaw(SAMPLES_NUMBER);
if(readingRaw == -2) mappedValue = 125; // tank full, water touches both metal probes, capacitance measurement not possible
else mappedValue = constrain(map(readingRaw, MIN_READING, MAX_READING, 0, 120), 0, 120); //map sensor reading to humidifier water level range (0 - 120)
packet[11] = mappedValue; //12th byte represents water level value
/* checksum calculation (A XOR B XOR C ... XOR 0xA0) */
for(int i = 0; i < 42; i++)
{
checksum ^= packet[i];
}
checksum ^= 0xA0;
/* checksum calculation */
packet[42] = checksum; //last byte checksum
Serial.write(packet, sizeof(packet));
//Serial.println(readingRaw); //for calibration
delay(100);
}