ecoMax800 is not connected #114

Open
3 of 10 tasks
Almaz90 opened this issue Jul 29, 2024 · 12 comments
Open
3 of 10 tasks

ecoMax800 is not connected #114

Almaz90 opened this issue Jul 29, 2024 · 12 comments
Labels
bug Something isn't working

Comments

@Almaz90
Copy link

Almaz90 commented Jul 29, 2024

Is there an existing issue for this?

  • I have searched the existing issues

I'm having the following issue:

Здравствуйте. Не удается подключить ecoMax 800R, он поддерживается данной интеграцией?
0
1
2

I have following devices connected:

  • ecoMAX 3xx series
  • ecoMAX 8xx series
  • ecoMAX 9xx series
  • Expansion module B
  • Expansion module C
  • ecoSTER 200/ecoSTER Touch
  • ecoLAMBDA
  • ecoNET 300

I'm connecting to my devices using:

USB to RS-485 adapter

I'm seeing following log messages:

No response

My diagnostics data:

No response

Code of Conduct

  • I agree to follow this project's Code of Conduct
@Almaz90 Almaz90 added the bug Something isn't working label Jul 29, 2024
@denpamusic
Copy link
Owner

denpamusic commented Jul 30, 2024

Hi,

Thank you for the feedback!

Sorry for delayed response, was offline for a couple days.

I checked diagnostics data, that we've collected from different devices and it seems that nobody tried the integration with EM800R device before, so I sadly cannot definitely confirm, that it is supported.

That being said, I've looked at manual for your device and I think it should work fine with this integration. It supports standard Plum modules like ecoLAMBDA and ecoSTER, which is good indicator that your device uses standard EM (ecoMAX) protocol as opposed to newer GM3 (GazModem 3), which we don't support yet.

From the error message, I can see that integration sees the connection, but fails to receive expected response from the EM.
This usually indicates hardware problem, so first things to try would be following:

  • swap D+ and D- wires around
  • try different rs485 ports (if your device has multiple)
  • try different USB to RS485 adapter, as FTB6SPL3 serial from your first screenshot, indicates that your adapter is built using fake FTDI chip, which are prone to failures (see first comment here)

@Taziff
Copy link

Taziff commented Jul 30, 2024

Can you write the software version of ecoMAX 800 module?

@Almaz90
Copy link
Author

Almaz90 commented Jul 30, 2024

Can you write the software version of ecoMAX 800 module?

panel v.01.20.22.B0
Module A: v.01.31.23.J1

@Almaz90
Copy link
Author

Almaz90 commented Jul 30, 2024

  • swap D+ and D- wires around
  • try different rs485 ports (if your device has multiple)
  • try different USB to RS485 adapter, as FTB6SPL3 serial from your first screenshot, indicates that your adapter is built using fake FTDI chip, which are prone to failures (see first comment here)

D+ and D- changed, the problem remained. I tried connecting to both G1 and G2 - the result is the same. I'll try to order another adapter.

@Taziff
Copy link

Taziff commented Jul 31, 2024

Can you write the software version of ecoMAX 800 module?

panel v.01.20.22.B0 Module A: v.01.31.23.J1

Unfortunately, this is the last version of the program which does not support econet300.

@denpamusic
Copy link
Owner

@Almaz90
Taziff has been very helpful with EM-related information during development of this project, so I think we can trust his information on the issue. I keep this open, just in case you get it working, but if EM doesn't support ecoNET, there's not a lot we can do sadly. Sorry.

@Taziff
Thank you for the info!

@Taziff
Copy link

Taziff commented Jul 31, 2024

Module A program v01 is from 2013r. There is a newer program, but there is a high chance that the module will be damaged during the update.

@Almaz90
Copy link
Author

Almaz90 commented Jul 31, 2024

Taziff has been very helpful with EM-related information during development of this project, so I think we can trust his information on the issue. I keep this open, just in case you get it working, but if EM doesn't support ecoNET, there's not a lot we can do sadly. Sorry.

I ordered USR-TCP232-304. If it doesn't work out with him, then we'll close the issue.

@Almaz90
Copy link
Author

Almaz90 commented Aug 10, 2024

Good afternoon. USR-TCP232-304 did not help, the problem remained. It looks like there really is a problem with the firmware

@denpamusic
Copy link
Owner

Good afternoon. USR-TCP232-304 did not help, the problem remained. It looks like there really is a problem with the firmware

Hi,

Thank you very much for heads up, although I'm really sorry to hear that :(
I seems that I'll need to compile at least some sort of (un)supported device list...

@Taziff
Copy link

Taziff commented Aug 10, 2024

There is newer software for this device that supports econet300, but there is a high probability that something will go wrong during the update.

@Almaz90
Copy link
Author

Almaz90 commented Aug 10, 2024

There is newer software for this device that supports econet300, but there is a high probability that something will go wrong during the update.

Is it possible to revive the block later?