diff --git a/content/docs/csidriver/troubleshooting/powermax.md b/content/docs/csidriver/troubleshooting/powermax.md
index 8a3c7cb54e..27af1ef2c4 100644
--- a/content/docs/csidriver/troubleshooting/powermax.md
+++ b/content/docs/csidriver/troubleshooting/powermax.md
@@ -20,4 +20,4 @@ description: Troubleshooting PowerMax Driver
| nodestage is failing with error `Error invalid IQN Target iqn.EMC.0648.SE1F` | 1. Update initiator name to full default name , ex: iqn.1993-08.org.debian:01:e9afae962192
2.Ensure that the iSCSI initiators are available on all the nodes where the driver node plugin will be installed and it should be full default name. |
| Volume mount is failing on few OS(ex:VMware Virtual Platform) during node publish with error `wrong fs type, bad option, bad superblock` | 1. Check the multipath configuration(if enabled) 2. Edit Vm Advanced settings->hardware and add the param `disk.enableUUID=true` and reboot the node |
| Standby controller pod is in crashloopbackoff state | Scale down the replica count of the controller pod's deployment to 1 using ```kubectl scale deployment --replicas=1 -n ``` |
-| When running CSI-PowerMax with Replication in a multi-cluster configuration, the driver on the target cluster fails and the following error is seen in logs: `error="CSI reverseproxy service host or port not found, CSI reverseproxy not installed properly"` | The reverseproxy service needs to be created manually on the target cluster. Follow [the instructions here](../../../deployment/csmoperator/modules/replication) to create it.|
+| When running CSI-PowerMax with Replication in a multi-cluster configuration, the driver on the target cluster fails and the following error is seen in logs: `error="CSI reverseproxy service host or port not found, CSI reverseproxy not installed properly"` | The reverseproxy service needs to be created manually on the target cluster. Follow [the instructions here](../../../deployment/csmoperator/modules/replication#configuration-steps) to create it.|