MMM-Fronius2

This is a module for the MagicMirror².

This module shows live data from a Fronius power converter (and more). There are already MM modules that show live data from Fronius power converters (hence the name), but they were lacking various features that I needed (see About section). So I decided to do my own implemetation.

About

The module has the following features:

  • Show live data of the power converter
  • Detect offline converter and show last fetched data
  • Send power data to MMM-EnergyMonitor (see below)

A word about extendability:

The module is designed in a way, that is is easily possible to support other power converters as well (depending on the fact that the devices have an interface to access data). If you have the need to support another manufacturer, please create an issue and/or create a pull request :).

Status

The current development status of this module is: maintained

This means: I'm open for feature requests, pull requests, bug reports, ...

Screenshots

Offline converter:

Using the module

To use this module, add the following configuration block to the modules array in the config/config.js file:

var config = {
    modules: [
        {
            module: 'MMM-Fronius2',
            config: {
                ip: "192.168.1.12", // Entering the IP of the power converter is mandatory
            }
        }
    ]
}

Configuration options

Please refer to MMM-Fronius2 default configuration to prevent syntax errors.

Option Description
ip Required The IP address if your power conferter
updateInterval Optional How often should the data be updated

Type: int (milliseconds)
Default: 3000 milliseconds (3 seconds)
wattConversionOptions Optional Configures if and how Watts should ge converted to kW, mW, gW

Type: object
See configuration below
wattConversionOptions.enabled Optional Turns the feature on/off

Type: boolean (on/off)
Default: true (on)
wattConversionOptions.threshold Optional At which value should numbers be converted

Type: int (Watt)
Default: 1200 Watt
wattConversionOptions.numDecimalDigits Optional To how many decimal digits should the converted value be shortened (keep this value low to prevent UI glitches)

Type: int
Default: 2 (example: 1.45 kW)
offlineDetectionOptions Optional Configures the offline detection of the power converter (for converters that are configured to turn off at night)

Type: object
See configuration below
offlineDetectionOptions.numRequests Optional The number of failed requests from which the converter should be considered offline

Type: int
Default: 5
offlineDetectionOptions.offlineInterval Optional The fetch interval for an offline converter

Type: int (millisecnods)
Default: 1800000 (30 Minutes)
requestTimeout Optional When should a request considered to be timed out

Type: int (milliseconds)
Default: 1000 milliseconds (1 second)
broadcastSolarPower Optional Should solar power data be broadcasted to MMM-EnergyMonitor

Type: boolean (on/off)
Default: false off
broadcastGridPower Optional Should grid power data be broadcasted to MMM-EnergyMonitor

Type: boolean (on/off)
Default: false off
broadcastBatteryPower Optional Should battery power data be broadcasted to MMM-EnergyMonitor

Type: boolean (on/off)
Default: false off

Special Thanks

Issues

If you find any problems, bugs or have questions, please open a GitHub issue in this repository.

Disclaimer

All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.