Notifications
You must be signed in to change notification settings - Fork 3
/
Copy pathdecoder_MerryIoT_Sensor_v1.0.0.js
166 lines (155 loc) · 8.28 KB
/
decoder_MerryIoT_Sensor_v1.0.0.js
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
// *** Browan Communications Inc. ***
//
// *** MerryIoT sensor decoder for JavaScript ***
// support parser type: MerryIoT Motion Detection(wsms-156), MerryIoT Air Quality CO2(wsms-157)
// MerryIoT Open/Close(wsms-158),MerryIoT Leak Detection(wsms-159)
//
// Author: Brian.Jiang
// Version v1.0.0
//
//sample test data
var test_payload = '000f3246a402';
var test_deveui = '00161600000023CC';
var test_fport = '127';
//hex to binary function
function hex2bin(hex){
return (parseInt(hex, 16).toString(2)).padStart(8, '0');
}
//CO2 ppm calculate
const changeEndianness = (string) => {
const result = [];
let len = string.length - 2;
while (len >= 0) {
result.push(string.substr(len, 2));
len -= 2;
}
return result.join('');
}
//decoder function
function decodepayload(input) {
// create the object to collect the data for returning the decoded payload
console.log('Fport: '+input.fport);
if(input.fport==122){ // MerryIoT Motion Sensor
var a = input.payload;
var b = a.toString('base64');
var motion_hex = b.toString("hex").substring(0, 2); // Sensor Status
var motion_binary = hex2bin(motion_hex);
var motion_st = motion_binary.substring(7, 8); // Motion status
var button_st = motion_binary.substring(6, 7); // Button pressed
var Tamper_st = motion_binary.substring(5, 6); // Tamper detected
var battry_hex = b.toString("hex").substring(2, 4);// battery calculate
var battry_int = parseInt(battry_hex, 16);
battry_volt = (21+battry_int)/10;
var temperature_hex = b.toString("hex").substring(4, 6);///temperature calculate
var temperature_int = parseInt(temperature_hex, 16);
var humi_hex = b.toString("hex").substring(6, 8);//Humidity calculate
var humi_int = parseInt(humi_hex, 16);
var time_hex = (b.toString('hex').substring(10, 12))+(b.toString('hex').substring(8, 10)); //Time elapsed since last event trigger
var time_int = parseInt(time_hex, 16);
var count_hex = (b.toString('hex').substring(16, 18))+(b.toString('hex').substring(14, 16))+(b.toString('hex').substring(12, 14)); //Total count of event triggers
var count_int = parseInt(count_hex, 16);
console.log('Sensor Type: Motion Sensor');
console.log('DeviceEUI: '+input.deveui);
console.log('Motion occupied: '+motion_st); //1 – occupied, 0 – free
console.log('Button pressed: '+button_st); //1 – Button pressed, 0 - Button released
console.log('Tamper detected: '+Tamper_st); //1 – Tamper detected, 0 - No tamper detected
console.log('Battery: '+battry_volt+' v');
console.log('Temperature: '+temperature_int+' oC');
console.log('Humidity: '+humi_int+' %RH');
console.log('Time: '+time_int);
console.log('Count: '+count_int);
}
else if(input.fport==127){// MerryIoT CO2 Sensor
var a = input.payload;
var b = a.toString('base64');
var status_hex = b.toString("hex").substring(0, 2); // Sensor Status
var status_binary = hex2bin(status_hex);
var trigger_st = status_binary.substring(7, 8); // Trigger Event
var button_st = status_binary.substring(6, 7); // Button pressed
var co2threshold_st = status_binary.substring(3, 4); // CO2 is over the threshold
var co2calibration_st = status_binary.substring(2, 3); // CO2 Calibration flag
var battry_hex = b.toString("hex").substring(2, 4);// battery calculate
var battry_int = parseInt(battry_hex, 16);
battry_volt = (21+battry_int)/10;
var temperature_hex = b.toString("hex").substring(4, 6);///temperature calculate
var temperature_int = parseInt(temperature_hex, 16);
var humi_hex = b.toString("hex").substring(6, 8);//Humidity calculate
var humi_int = parseInt(humi_hex, 16);
var co2_hex = b.toString("hex").substring(8, 12); // CO2 calculate
var co2_total = changeEndianness(co2_hex);
co2_int = parseInt(co2_total, 16);
console.log('Sensor Type: CO2 Sensor');
console.log('DeviceEUI: '+input.deveui);
console.log('Trigger Event: '+trigger_st); //1 – Trigger Event, 0 – Keepalive
console.log('Button pressed: '+button_st); //1 – Button pressed, 0 - Button released
console.log('CO2 over threshold: '+co2threshold_st); //1 - CO2 is over the threshold (CO2 > 1000 ppm)
console.log('CO2 Calibration flag: '+co2calibration_st); //1 - CO2 Calibration flag
console.log('Battery: '+battry_volt+' v');
console.log('Temperature: '+temperature_int+' oC');
console.log('Humidity: '+humi_int+' %RH');
console.log('CO2: '+co2_int+' ppm');
}
else if(input.fport==120){// MerryIoT door/window Sensor
var a = input.payload;
var b = a.toString('base64');
var door_hex = b.toString("hex").substring(0, 2); // Sensor Status
var door_binary = hex2bin(door_hex);
var open_st = door_binary.substring(7, 8); // Door status
var button_st = door_binary.substring(6, 7); // Button pressed
var tamper_st = door_binary.substring(5, 6); // Tamper detected
var tilt_st = door_binary.substring(4, 5); // Tilt detected
var battry_hex = b.toString("hex").substring(2, 4);// battery calculate
var battry_int = parseInt(battry_hex, 16);
battry_volt = (21+battry_int)/10;
var temperature_hex = b.toString("hex").substring(4, 6);///temperature calculate
var temperature_int = parseInt(temperature_hex, 16);
var humi_hex = b.toString("hex").substring(6, 8);//Humidity calculate
var humi_int = parseInt(humi_hex, 16);
var time_hex = (b.toString('hex').substring(10, 12))+(b.toString('hex').substring(8, 10)); //Time elapsed since last event trigger
var time_int = parseInt(time_hex, 16);
var count_hex = (b.toString('hex').substring(16, 18))+(b.toString('hex').substring(14, 16))+(b.toString('hex').substring(12, 14)); //Total count of event triggers
var count_int = parseInt(count_hex, 16);
console.log('Sensor Type: Door/window Sensor');
console.log('DeviceEUI: '+input.deveui);
console.log('Door open: '+open_st); //1 - open, 0 - closed
console.log('Button pressed: '+button_st); //1 - Button pressed, 0 - Button released
console.log('Tamper detected: '+tamper_st); //1 – Tamper detected, 0 - No tamper detected
console.log('Tilt detected: '+tilt_st); //1 - Tilt detected, 0 - No Tilt detected
console.log('Battery: '+battry_volt+' v');
console.log('Temperature: '+temperature_int+' oC');
console.log('Humidity: '+humi_int+' %RH');
console.log('Time: '+time_int);
console.log('Count: '+count_int);
}
else if(input.fport==126){// MerryIoT WaterLeak Sensor
var a = input.payload;
var b = a.toString('base64');
var water_hex = b.toString("hex").substring(0, 2); // Sensor Status
var water_binary = hex2bin(water_hex);
var waterDT_st = water_binary.substring(7, 8); // water status
var button_st = water_binary.substring(6, 7); // Button pressed
var tamper_st = water_binary.substring(5, 6); // Tamper detected
var battry_hex = b.toString("hex").substring(2, 4);// battery calculate
var battry_int = parseInt(battry_hex, 16);
battry_volt = (21+battry_int)/10;
var temperature_hex = b.toString("hex").substring(4, 6);///temperature calculate
var temperature_int = parseInt(temperature_hex, 16);
var humi_hex = b.toString("hex").substring(6, 8);//Humidity calculate
var humi_int = parseInt(humi_hex, 16);
console.log('Sensor Type: WaterLeak Sensor');
console.log('DeviceEUI: '+input.deveui);
console.log('Water detected: '+waterDT_st); //1 – Water leakage detected, 0 – Dry
console.log('Button pressed: '+button_st); // 1 – Button pressed, 0 - Button released
console.log('Tamper detected: '+tamper_st); //1 – Tamper detected, 0 - No tamper detected
console.log('Battery: '+battry_volt+' v');
console.log('Temperature: '+temperature_int+' oC');
console.log('Humidity: '+humi_int+' %RH');
}
}
var sensor_origin = {
"fport" : test_fport, // lorawan port
"deveui": test_deveui, // device eui
"payload": test_payload, // original payload
};
//Test function output
decodepayload(sensor_origin);