import machine
import sds011
import bme280 as bme280
import time
import struct
from sx127x import TTN, SX127x
from machine import Pin, SPI
from config import *
import json
import math
import network
i2c = machine.I2C(0, sda=machine.Pin(21), scl=machine.Pin(22))
bme = bme280.BME280(i2c=i2c)
uart = machine.UART(2,baudrate=9600, bits=8, parity=None, stop=1, rx=16, tx=17)
dust_sensor = sds011.SDS011(uart)
__DEBUG__ = True
ttn_config = TTN(ttn_config['devaddr'], ttn_config['nwkey'], ttn_config['app'], country=ttn_config['country'])
device_spi = SPI(device_config['spi_unit'], baudrate = 10000000,
polarity = 0, phase = 0, bits = 8, firstbit = SPI.MSB,
sck = Pin(device_config['sck'], Pin.OUT, Pin.PULL_DOWN),
mosi = Pin(device_config['mosi'], Pin.OUT, Pin.PULL_UP),
miso = Pin(device_config['miso'], Pin.IN, Pin.PULL_UP))
lora = SX127x(device_spi, pins=device_config, lora_parameters=lora_parameters, ttn_config=ttn_config)
frame_counter = 0
def on_receive(lora, outgoing):
payload = lora.read_payload()
print(payload)
def do_connect():
import network
sta_if = network.WLAN(network.STA_IF)
sta_if.config(hostname="Micropython-Weather")
if not sta_if.isconnected():
print('connecting to network...')
sta_if.active(True)
sta_if.connect(wifi_config['ssid'], wifi_config['password'])
while not sta_if.isconnected():
pass
print('network config:', sta_if.ifconfig())
lora.on_receive(on_receive)
lora.receive()
do_connect()
while True:
dust_sensor.wake()
time.sleep(5)
#Returns NOK if no measurement found in reasonable time
status = dust_sensor.read()
#Returns NOK if checksum failed
pkt_status = dust_sensor.packet_status
if(status == False):
print('Measurement failed.')
pm25,pm10=(0.0,0.0)
elif(pkt_status == False):
print('Received corrupted data.')
pm25,pm10=(0.0,0.0)
else:
pm25=float(dust_sensor.pm25)
pm10=float(dust_sensor.pm10)
dust_sensor.sleep()
temperature,pressure,humidity = bme.values
temp = math.ceil(float(temperature[:-1]))
press = math.ceil(float(pressure[:-3]))
hum = math.ceil(float(humidity[:-1]))
print(f"{temp},{press},{hum},{pm10},{pm25}")
payload = struct.pack('>IIIdd',temp,press,hum,pm25,pm10) #struct format int,int,int,double,double
lora.send_data(data=payload, data_length=len(payload), frame_counter=frame_counter)
lora.receive()
frame_counter += 1
for i in range(app_config['loop']):
time.sleep_ms(app_config['sleep'])