- ChangeBuildingLocation CSV encoding
- fix sim osw typo
- ruby 3.2.2 exists
- v1.2.0 performance regression
- openstudio standards 0.6.1 patch
- OpenStudio v3.8.0
- EnergyPlus v24.1.0
- OpenStudio v3.6.0
- EnergyPlus v23.1.0
- Measure fixes
- Jira-REVIT-218565
- OpenStudio v3.6.0
- EnergyPlus v23.1.0
- Measure fixes:
- REVIT-210122
- REVIT-213603
- OpenStudio v3.6.0
- EnergyPlus v23.1.0
- Measure fixes
- OpenStudio updated to v3.6.0
- EnergyPlus updated to v23.1.0
- Switched EnergyPlus to build with
LINK_WITH_PYTHON
off to avoid including Python stdlib
- Updated Systems Analysis Reports French translations
- Fixed simulations for nameless buildings
- Reporting improvements
- Reporting improvements
- gbXML import improvements
- OpenStudio updated to v3.4.0
- EnergyPlus updated to v22.1.0
- Measures updated for compatibility
- Updated from v1.0.4 base
- Truncated unused OpenSSL dlls
- [Beta Build]
- OpenStudio updated to v3.3.0
- EnergyPlus updated to v9.6.0
- Ruby updated to v2.7.2
- gbXML import performance improvements
- Minor changes to support OpenStudio v3.0.0
- Charts for the zone and system load summary PDF
- Updated Design Psychrometrics PDF
- Alignment for long words in the summary content
- Issue preventing the PDF from opening in Adobe
- Updated the report PDF view for the tables. Charts don't render yet.
- Removed on hover tooltip from the dropdown selector
- Reintroduced the print button
- Various localization fixes
- When no zones/systems/coils found
- Acronyms are now translated
- Unit system dropdown is now localized
- Styling that caused the left side of the report to be cut off when using a narrow window
- Pie chart labels fixed to support 6 sig. fig.
- The HTML view design has been updated to the specification
- The locale button has been removed
- The print button has been removed
- Units button now states "units" after the unit system.
- A fix for E+ reporting OA as a decimal has been implemented
- Localization for some additional words have been added.
- Various unit conversions including temperature and power
- Eplusout now covers edge cases where E+ stores % incorrectly.
- Conversion layer to work with E+ simulations run in IP or SI
- Reading the configuration file from the simulation root
- Debug mode to write the data out as a JSON file
- Fixed Psychrometric map from rendering mixed unit systems. Defaults to IP now even if Revit units are selected.
- Updated the Design Psychometrics to show the state point of air in the table
- Added a psychrometric chart as a visualization for Design Psychrometrics
- Added localization to the labels
- Added client-side printing although issues with localization still need to be addressed
- Performance issues related to the annual and weekly schedules being inferred from the Building Type
- Activity Schedules regression
- Inference of annual and weekly schedules from the Building Type
- Improved absorptance property import to prevent issue related to material present on more than one construction outer layer.
- Merged OpenStudio Results and eplustbl.htm report
- Both sizing and annual reports write to openstudio_results_report.html
- Removed the "OpenStudio Results" header from the annual simulation report
- "OpenStudio Results" changed to "Annual Simulation Report" in the html title.
- Global sizing factors added to set_simulation_control measure with default at 1.0 for heating and cooling
- Changed the OSW names to "Annual Building Energy Simulation.osw" and "HVAC Systems Loads and Sizing.osw"
- Updated sizing schedules to be all off for heating and all on for cooling
- Weather file measure now grabs the most stringent percentiles available and falls back to less stringent if unavailable
- Infiltration set on a per unit of exterior wall area rather than all exterior area
- IP units electricity consumption issue on the openstudio_results html report.
- Redundant code
- Setpoint Manager at 4C on the preheat coil to temper the incoming outdoor air stream
- Zone equipment respond to the draw ventilation parameter
- Support for material solar absorptance
- eplustbl.html now respond to the output units desired by the gbXML file
- Sensible heat ratio of people load is translated correctly
- Adjusted zone equipment load priority so that air terminals on a DOAS are lowest ensuring they only respond to ventilation.
- Zone equipment that provide outdoor air directly now have a constant volume fan so ventilation is always met
- Made the chilled water a variable speed setup
- VAV boxes on a DOAS control for outdoor air to enable DCV
- Set the solar distribution algorithm to 'FullExterior' from 'Minimal Shadowing'
- Resolved issue with chilled water supplying at the loop temperature delta rather than design
- Removed the loads_out.json report
- Added the ability for an Air System to operate as a DOAS
- Zone sizing temperatures are now determined by the type of equipment serving that zone
- Made zone equipment aware of their zones to allow for two-way data traversal
- Altered the zone sizing objects to account for the effect of a DOAS
- Altered the System sizing objects to account for the effect of a DOAS
- Changed the zone HVAC Equipment design supply temperatures
- Adjusted the structure of the HVAC measure to be more consistent across systems
- Added a fluid cooler rather than cooling tower to condenser loops to be more representative for WSHP systems when present
- Adjusted the design temperatures of most HVAC systems to be more representative of typical design
- Set the location/weather file at the top of the workflow to allow design days to set the incoming air temperature for sizing of preheat coils
- Moved the preheat coil into the incoming outdoor air stream to allow E+ to size it more accurately
- Allowed chilled water loops to size for radiant-like temperatures when no lower temperature equipment are on the loop
- Removed fan power from passive chilled beams and radiant panels as a FPFC approximation is being used
- Added post-build step to decouple object creation from connecting nodes
- Fixed FPFC bug in the reporting that caused the simulation to fail