diff --git a/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md b/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md index 4752c70a965..786ca248433 100644 --- a/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md +++ b/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md @@ -8,7 +8,11 @@ Describe input change here Use links like: [PR#9480](https://github.com/NREL/EnergyPlus/pull/9480/) -# Object Change: Coil:Cooling:DX:CurveFit:Performance +# Object Changes: New Crankcase Heat Capacity Function of Temperature Curve for all DX coils + +[PR#9949](https://github.com/NREL/EnergyPlus/pull/9949/) + +## Object Change: Coil:Cooling:DX:CurveFit:Performance Field 1 to 2 remain the same. @@ -16,7 +20,7 @@ Field 3 is a new field named "Crankcase Heater Capacity Function of Temperature Field 4 and onwards are the same. -# Object Change: Coil:Cooling:DX:SingleSpeed +## Object Change: Coil:Cooling:DX:SingleSpeed Field 1 to 26 remain the same. @@ -24,7 +28,7 @@ Field 27 is a new field named "Crankcase Heater Capacity Function of Temperature Field 28 and onwards are the same. -# Object Change: Coil:Cooling:DX:MultiSpeed +## Object Change: Coil:Cooling:DX:MultiSpeed Field 1 to 12 remain the same. @@ -32,7 +36,7 @@ Field 13 is a new field named "Crankcase Heater Capacity Function of Temperature Field 14 and onwards are the same. -# Object Change: Coil:Cooling:DX:VariableSpeed- +## Object Change: Coil:Cooling:DX:VariableSpeed Field 1 to 14 remain the same. @@ -40,7 +44,7 @@ Field 15 is a new field named "Crankcase Heater Capacity Function of Temperature Field 16 and onwards are the same. -# Object Change: Coil:Cooling:DX:TwoStageWithHumidityControlMode- +## Object Change: Coil:Cooling:DX:TwoStageWithHumidityControlMode Field 1 to 5 remain the same. @@ -48,7 +52,7 @@ Field 6 is a new field named "Crankcase Heater Capacity Function of Temperature Field 7 and onwards are the same. -# Object Change: Coil:Heating:DX:SingleSpeed- +## Object Change: Coil:Heating:DX:SingleSpeed Field 1 to 19 remain the same. @@ -56,7 +60,7 @@ Field 20 is a new field named "Crankcase Heater Capacity Function of Temperature Field 21 and onwards are the same. -# Object Change: Coil:Heating:DX:MultiSpeed +## Object Change: Coil:Heating:DX:MultiSpeed Field 1 to 7 remain the same. @@ -64,7 +68,7 @@ Field 8 is a new field named "Crankcase Heater Capacity Function of Temperature Field 9 and onwards are the same. -# Object Change: Coil:Heating:DX:VariableSpeed- +## Object Change: Coil:Heating:DX:VariableSpeed Field 1 to 13 remain the same. @@ -72,7 +76,7 @@ Field 14 is a new field named "Crankcase Heater Capacity Function of Temperature Field 15 and onwards are the same. -# Object Change: Coil:WaterHeating:AirToWaterHeatPump:Pumped- +## Object Change: Coil:WaterHeating:AirToWaterHeatPump:Pumped Field 1 to 19 remain the same. @@ -80,7 +84,7 @@ Field 20 is a new field named "Crankcase Heater Capacity Function of Temperature Field 21 and onwards are the same. -# Object Change: Coil:WaterHeating:AirToWaterHeatPump:Wrapped +## Object Change: Coil:WaterHeating:AirToWaterHeatPump:Wrapped Field 1 to 12 remain the same. @@ -88,7 +92,7 @@ Field 13 is a new field named "Crankcase Heater Capacity Function of Temperature Field 14 and onwards are the same. -# Object Change: Coil:WaterHeating:AirToWaterHeatPump:VariableSpeed- +## Object Change: Coil:WaterHeating:AirToWaterHeatPump:VariableSpeed Field 1 to 18 remain the same.