Skip to content

PYNQ example

Alireza Khodamoradi edited this page Oct 2, 2018 · 9 revisions

PYNQ Example Tutorial

In this example we implement f(x) = 2x as an IP on PYNQ.

1) Vivado_HLS: C/C++ to RTL

In this section, you will write your code in C/C++, test it, and convert it to RTL using Vivad_HLS.

1.1) Write your code

Open Vivado_HLS, create a new project, and name it pynq_mul.

new HLS project

Set top function name to mul_test

top function

Do not add any files to your project and proceed to part selection and select xcz020clg400-1.

part number

In Explorer section, right click on Source, select New file and create mul_test.cpp. Complete the body of mul.cpp as following:

void mul_test(int* out, int in){
	*out = 2*in;
}

Create a test bench file by right clicking on Test Bench in Explorer section and create a new file named mul_tb.cpp. Complete the body of this file as following:

#include <iostream>

using namespace std;

void mul_test(int* out, int in);

int main(int argc, char *argv[]){
	int x=5;
	int y;
	mul_test(&y, x);
	if(y!=2*x){
		cout << "Test Failed: output(" << y << ") is not equal to 2x" << x << endl;
	}else{
		cout << "Test Passed" << endl;
	}
	return 0;
}

hls files

1.2) Test your code

Run C simulation and make sure your code passes your test bench.

1.3) Set port types

Make sure that mul_test.cpp is open. Open Directive on right side and set all the ports to s_axilite by right clicking on available options in Directive window.

directives

1.4) Synthesis and export your design

Run C Synthesis and after finished, click on export RTL and export your design.

At this point, you can exit and close Vivado_HLS.

2) Vivado: RTL to bitstream

In this section, you will import your RTL code to Vivado and generate a bitstream.

2.1) Create a new project

Open Vivado and create a new project and Name your project as mul_test.

new project1

Select RTL Project and check Do not specify sources at this time.

new project2

Set default part to xcz020clg400-1.

vivado part

Under Project Manager, click on Create Block Design

block diagram

2.2) Import your design

Under Project Manager, click on IP Catalog. Right click on the open window and select Add Repository. In the open window navigate to your Vivado_HLS project folder and select pass_to_vivado_hls_folder\solution1\impl\ip

import

In IP Catalog search for mul_test and add it to your block design.

add ip

2.3) Add connections

Go back to IP Catalog and add ZYNQ7 Processing System to your block design.

add zynq

Your diagram should look like the following:

pre connection

On top of Diagram window, first click and complete Run Block Automation and then Run Connection Automation with default settings. Your diagram should change and show connections and a couple of extra IPs:

post connection

2.4) Generate bitstream

In Sources, right click on design_1 and select Create HDL Wrapper.

post connection

Under Project Manager, click on Generate Bitstream to build .bit and .tcl files.

2.5) Bitstream, tcl, and addresses

Before closing Vivado, we need to note our IP and its ports addresses:

Under Sources, open mul_test_mul_io_s_axi.v. Scroll down and note addresses for in and out ports. We need these addresses for our host program.

addresses

Under Address Editor note IP's address

addresses

3) PYNQ board and Host program

Using SMB or SCP, copy design_1_wrapper.bit and design_1_wrapper.tcl from vivado_project_path\mul_test.runs\impl1 to your PYNQ board at /home/xilinx/jupyter_notebooks/mul_test.

Open a new Notebook and run the following code to test your IP

from pynq import Overlay
from pynq import MMIO

ol = Overlay("/home/xilinx/jupyter_notebooks/mul_test/design_1_wrapper.bit")
ol.download()

mul_ip=MMIO(0x43C00000, 0x10000)

mul_ip.write(0x18, 5)
print("add a:", add_ip.read(0x18)) 
mul_ip.write(0x00, 1)
print("add y:", add_ip.read(0x10)) 
Clone this wiki locally